The Case,sterilization, cataloged under National Stock Number 6530-01-421-1391, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Steris Corporation Dba Steris Applied Sterilization Technololgies. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6530-01-421-1391 |
| Primary Part Number | CD66B |
| Item Name | Case,sterilization |
| FSC / FSG | 6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies |
| Manufacturer | Steris Corporation Dba Steris Applied Sterilization Technololgies |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| CD66B PRIMARY | Steris Corporation Dba Steris Applied Sterilization Technololgies (USA) |
| CD6-6B PRIMARY | Carefusion 2200 Inc (USA) |
| Reference | Meaning |
|---|---|
| CD6-6B | 5/9 Secondary reference Cardinal Health 200, Llc |
| CD 6-6 | 5/9 Secondary reference Genesis Medical Inc |
| 95-0604 | 5/1 Secondary reference U.S. Government activity |
NSN 6530-01-421-1391 is a Case,sterilization, manufactured by Steris Corporation Dba Steris Applied Sterilization Technololgies, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.
NSN 6530-01-421-1391 has 2 manufacturer part numbers on file: CD66B (Steris Corporation Dba Steris Applied Sterilization Technololgies), CD6-6B (Carefusion 2200 Inc).
Key specifications for CD66B: Special Features: RIGID; RETRACTOR; 26 IN. LONG BY 17 IN. WIDE BY 6 IN. DEEP; C/O: RETRACTOR LID, 1; RETRACTOR BOTTOM, 1; TOP AND BOTTTOM FABRICATED OF AN ALUMINUM ALLOY THAT HAS BEEN PROPERLY HARDENED AND PASSIVATED; HAS MULTIPLE PERFORATIONS FOR AIR REMOVAL AND STEAM PENETRATION THROUGH THE USE OF A FILTER; HAS REMOVABLE FILTER RETENTION PLATE FOR INSERTION OF A PAPER FILTER; TWO COLLAPSIBLE HANDLES FOR CARRYING; FRONT OF CASE HAS AN AREA FOR PLACEMENT OF AN IDENTIFICATION LABEL OF THE CONTENTS, A PROCESS INDICATOR CARD AND A TAMPERPROOF LOCK; CAPABLE OF REPEATED STERILIZATION PROCESSES BY STEAM AT 270 DEG FAHRENHEIT FOR 20 MINUTES; ALSO SUITABLE FOR STORAGE AND TRANSPORTATION OF SURGICAL INSTRUMENTS IN; Part Name Assigned by Controlling Agency: CASE STERILZ RIGID RETRACTOR 26X17X6"FOR STORAGE & TRANSPORT; End Item Identification: 6530-01-423-2849, BASKET,STERILIZATION,SURGICAL INSTRUMENT. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.