PartsTable TECHNICAL DATA SHEET
NSN 6530-01-287-4213Government record, cited

Ultrasonic Apparatus and Muscle6530-01-287-4213

NSN 6530-01-287-4213 · NIIN 012874213 · Part number RM IV
Rich-Mar Corporation Dba Artison Corporation · FSC 6530 — Hospital Furniture, Equipment, Utensils, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 65265
Government record, cited
NSN 6530-01-287-4213 — this item is cataloged by the U.S. Government under National Stock Number 6530-01-287-4213. Manufacturer of record part number: RM IV.
Also searched as  6530-01-287-4213 · 6530012874213 · NIIN 012874213 · 01-287-4213 · FSC 6530 Hospital Furniture, Equipment, Utensils, and Supplies · CAGE 65265 · RM IV
Nearby stock numbers  ·
Features
  • Ultrasonic Apparatus and Muscle — FSC 6530
  • Departure From Cited Document: PEACETIME DEMAND OBTAIN
  • 1 manufacturer part number on file
  • Manufacturer of record: Rich-Mar Corporation Dba Artison Corporation
Identification
  • NSN: 6530-01-287-4213
  • NIIN: 012874213
  • FSC: 6530 — Hospital Furniture, Equipment, Utensils, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: RM IV
  • Manufacturer: Rich-Mar Corporation Dba Artison Corporation
General Description

The Ultrasonic Apparatus and Muscle, cataloged under National Stock Number 6530-01-287-4213, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Rich-Mar Corporation Dba Artison Corporation. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6530-01-287-4213
Primary Part NumberRM IV
Item NameUltrasonic Apparatus and Muscle
FSC / FSG6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies
ManufacturerRich-Mar Corporation Dba Artison Corporation
StatusACTIVE
Departure From Cited DocumentPEACETIME DEMAND OBTAIN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
RM IV PRIMARY Rich-Mar Corporation Dba Artison Corporation (USA)
No interchangeability data on file.
Other items in FSC 6530 — Hospital Furniture, Equipment, Utensils, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6530-00-003-5096
6530-00-003-5096 · Item name not on file
6530-00-003-5137
6530-00-003-5137 · Item name not on file
6530-00-003-5185
6530-00-003-5185 · Item name not on file
6530-00-004-4189
6530-00-004-4189 · Item name not on file
6530-00-005-3929
6530-00-005-3929 · Item name not on file
6530-00-006-3497
CHAIR,COMMODE
6530-00-006-4719
6530-00-006-4719 · Item name not on file
6530-00-006-5948
6530-00-006-5948 · Item name not on file

Frequently Asked Questions

What is NSN 6530-01-287-4213?

NSN 6530-01-287-4213 is a Ultrasonic Apparatus and Muscle, manufactured by Rich-Mar Corporation Dba Artison Corporation, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.

What part numbers are listed for NSN 6530-01-287-4213?

NSN 6530-01-287-4213 has 1 manufacturer part number on file: RM IV (Rich-Mar Corporation Dba Artison Corporation).

What are the specifications of RM IV?

Key specifications for RM IV: Departure From Cited Document: PEACETIME DEMAND OBTAIN; Special Features: PORTABLE ULTRASONIC THERAPY DEVICE; 115 V, 50/60 HZ, AC: 135 WATTS; RADIATION AT FREQ BETWEEN 0.8 TO 1.0 MHZ; PULSE OUTPUT POWER 20 W; VARIABLE RATE FROM 5-60 PULSES/SEC; PROVIDED W/TRANSDUCER APPLICATOR; PORTABLE ELECTRIC MUSCLE STIMULATOR FOR PHYSICAL THERAPY TREATMENT; 115 V, 50/60 HZ, AC: C/O LOW VOLTAGE MUSCLE STIMULATOR AND GALVANIC DC GENERATOR; ADJUSTABLE FROM 0.0 TO 50.0 MA; INTERRUPTED RATE SELECTABLE FROM 1.0 TO 6.0 PULSES/SEC; 1.0 TO 6.0 PULSES/SEC; 1.0 TO 15 MIN TIMER; W/4 APPLICATION PADS MHz; Part Name Assigned by Controlling Agency: ULTRASONIC APPARATUS & MUSCLE STIMULATOR PORTABLE115V50/60HZ135W. 1 specification is documented in the U.S. Government catalog.

Is NSN 6530-01-287-4213 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com