PartsTable TECHNICAL DATA SHEET
NSN 6530-01-210-4452Government record, cited

Heater Element Assembly6530-01-210-4452

NSN 6530-01-210-4452 · NIIN 012104452 · Part number P078826091
Steris Corporation Dba Steris Applied Sterilization Technololgies · FSC 6530 — Hospital Furniture, Equipment, Utensils, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0NWN1
Government record, cited
NSN 6530-01-210-4452 — this item is cataloged by the U.S. Government under National Stock Number 6530-01-210-4452. Manufacturer of record part number: P078826091.
Also searched as  6530-01-210-4452 · 6530012104452 · NIIN 012104452 · 01-210-4452 · FSC 6530 Hospital Furniture, Equipment, Utensils, and Supplies · CAGE 0NWN1 · P078826091
Nearby stock numbers  ·
Features
  • Heater Element Assembly — FSC 6530
  • General Characteristics Item Description: 20 KW 208 V,FLANGE MOUNTED HEATING ELEMENTS; 0.750 IN. THICH,6.000 IN. IN DIA,150 LB TEST FORGED STEEL FLANGE; W/FOUR DRILLED HOLES,0.750 IN. DIA,4.750 IN. DIA. ON FLANGE; STAINLESS STEEL SHEATH,29.875 IN. IN LENGTH; 1.125 IN. FROM TOP OF FLANGE TO TIP END OF SHEATH V
  • Reference Data and Literature: AMERICAN STERILIZER COMPANY DWG. NO. 78826
  • Purchase Description Identification: 02964-78826-091
  • Cubic Measure: 0.065 CUBIC FEET
  • 1 manufacturer part number on file
  • Manufacturer of record: Steris Corporation Dba Steris Applied Sterilization Technololgies
Identification
  • NSN: 6530-01-210-4452
  • NIIN: 012104452
  • FSC: 6530 — Hospital Furniture, Equipment, Utensils, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: P078826091
  • Manufacturer: Steris Corporation Dba Steris Applied Sterilization Technololgies
General Description

The Heater Element Assembly, cataloged under National Stock Number 6530-01-210-4452, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Steris Corporation Dba Steris Applied Sterilization Technololgies. Government technical data includes 4 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6530-01-210-4452
Primary Part NumberP078826091
Item NameHeater Element Assembly
FSC / FSG6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies
ManufacturerSteris Corporation Dba Steris Applied Sterilization Technololgies
StatusACTIVE
General Characteristics Item Description20 KW 208 V,FLANGE MOUNTED HEATING ELEMENTS; 0.750 IN. THICH,6.000 IN. IN DIA,150 LB TEST FORGED STEEL FLANGE; W/FOUR DRILLED HOLES,0.750 IN. DIA,4.750 IN. DIA. ON FLANGE; STAINLESS STEEL SHEATH,29.875 IN. IN LENGTH; 1.125 IN. FROM TOP OF FLANGE TO TIP END OF SHEATH V
Reference Data and LiteratureAMERICAN STERILIZER COMPANY DWG. NO. 78826
Purchase Description Identification02964-78826-091
Cubic Measure0.065 CUBIC FEET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
P078826091 PRIMARY Steris Corporation Dba Steris Applied Sterilization Technololgies (USA)
Reference documents
ReferenceMeaning
P078826091 3/9 Design control — primary reference
American Sterilizer Company Dba Amsco Sterility Assurance Products

Frequently Asked Questions

What is NSN 6530-01-210-4452?

NSN 6530-01-210-4452 is a Heater Element Assembly, manufactured by Steris Corporation Dba Steris Applied Sterilization Technololgies, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.

What part numbers are listed for NSN 6530-01-210-4452?

NSN 6530-01-210-4452 has 1 manufacturer part number on file: P078826091 (Steris Corporation Dba Steris Applied Sterilization Technololgies).

What are the specifications of P078826091?

Key specifications for P078826091: General Characteristics Item Description: 20 KW 208 V,FLANGE MOUNTED HEATING ELEMENTS; 0.750 IN. THICH,6.000 IN. IN DIA,150 LB TEST FORGED STEEL FLANGE; W/FOUR DRILLED HOLES,0.750 IN. DIA,4.750 IN. DIA. ON FLANGE; STAINLESS STEEL SHEATH,29.875 IN. IN LENGTH; 1.125 IN. FROM TOP OF FLANGE TO TIP END OF SHEATH V; Reference Data and Literature: AMERICAN STERILIZER COMPANY DWG. NO. 78826; Purchase Description Identification: 02964-78826-091; Cubic Measure: 0.065 CUBIC FEET. 4 specifications are documented in the U.S. Government catalog.

Is NSN 6530-01-210-4452 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.