PartsTable TECHNICAL DATA SHEET
NSN 6530-01-119-7682Government record, cited

Ultrasonic Apparatus and Muscle6530-01-119-7682

NSN 6530-01-119-7682 · NIIN 011197682 · Part number RM IV W/PROVISIONING
Rich-Mar Corporation Dba Artison Corporation · FSC 6530 — Hospital Furniture, Equipment, Utensils, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 65265
Government record, cited
NSN 6530-01-119-7682 — this item is cataloged by the U.S. Government under National Stock Number 6530-01-119-7682. Manufacturer of record part number: RM IV W/PROVISIONING.
Also searched as  6530-01-119-7682 · 6530011197682 · NIIN 011197682 · 01-119-7682 · FSC 6530 Hospital Furniture, Equipment, Utensils, and Supplies · CAGE 65265 · RM IV W/PROVISIONING
Nearby stock numbers  ·
Features
  • Ultrasonic Apparatus and Muscle — FSC 6530
  • 1 manufacturer part number on file
  • Manufacturer of record: Rich-Mar Corporation Dba Artison Corporation
Identification
  • NSN: 6530-01-119-7682
  • NIIN: 011197682
  • FSC: 6530 — Hospital Furniture, Equipment, Utensils, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: RM IV W/PROVISIONING
  • Manufacturer: Rich-Mar Corporation Dba Artison Corporation
General Description

The Ultrasonic Apparatus and Muscle, cataloged under National Stock Number 6530-01-119-7682, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Rich-Mar Corporation Dba Artison Corporation. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6530-01-119-7682
Primary Part NumberRM IV W/PROVISIONING
Item NameUltrasonic Apparatus and Muscle
FSC / FSG6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies
ManufacturerRich-Mar Corporation Dba Artison Corporation
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
RM IV W/PROVISIONING PRIMARY Rich-Mar Corporation Dba Artison Corporation (USA)
No interchangeability data on file.
Other items in FSC 6530 — Hospital Furniture, Equipment, Utensils, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6530-00-003-5096
6530-00-003-5096 · Item name not on file
6530-00-003-5137
6530-00-003-5137 · Item name not on file
6530-00-003-5185
6530-00-003-5185 · Item name not on file
6530-00-004-4189
6530-00-004-4189 · Item name not on file
6530-00-005-3929
6530-00-005-3929 · Item name not on file
6530-00-006-3497
CHAIR,COMMODE
6530-00-006-4719
6530-00-006-4719 · Item name not on file
6530-00-006-5948
6530-00-006-5948 · Item name not on file

Frequently Asked Questions

What is NSN 6530-01-119-7682?

NSN 6530-01-119-7682 is a Ultrasonic Apparatus and Muscle, manufactured by Rich-Mar Corporation Dba Artison Corporation, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.

What part numbers are listed for NSN 6530-01-119-7682?

NSN 6530-01-119-7682 has 1 manufacturer part number on file: RM IV W/PROVISIONING (Rich-Mar Corporation Dba Artison Corporation).

What are the specifications of RM IV W/PROVISIONING?

Key specifications for RM IV W/PROVISIONING: Special Features: PORTABLE ULTRASONIC THERAPY DEVICE; 115 V, 50/60 HZ, AC: RADIATION AT FREQUENCY BETWEEN 0.8 TO 1.0 MHZ; PULSE OUTPUT POWER 20 WATTS; VARIABLE RATE FROM 5 TO 60 PULSES/SEC; PROVIDED W/TRANSDUCER APPLICATOR; PORTABLE ELECTRIC MUSCLE STIMULATOR FOR PHYSICAL THERAPY TREATMENT; 115 V, 50/60 HZ, AC: C/O LOW VOLTAGE MUSCLE STIMULATOR AND GALVANIC DC GENERATOR, ADJUSTABLE FROM 0.0 TO 50.0 MA; INTERRRUPTED RATE SELECTABLE FROM 1.0 TO 60 PULSES/SEC; RECIPROCAL RATE SELECTIVE FROM 1.0 TO 6.0 PULSES/SEC; 1.0 TO 15 MIN TIMER; W/4 APPLICATOR PADS; FOR USE IN FIELD ASSEMBLIES MHz; Part Name Assigned by Controlling Agency: ULTRASONIC APPARATUS & MUSCLE STIMULATOR 115V 50/60HZ PORTABLE V. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6530-01-119-7682 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com