The Preservation System,kidney, cataloged under National Stock Number 6530-00-149-0125, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Zareba Systems Inc. Div Waters Medical Systems/zareba Systems. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6530-00-149-0125 |
| Primary Part Number | M0X100 |
| Item Name | Preservation System,kidney |
| FSC / FSG | 6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies |
| Manufacturer | Zareba Systems Inc. Div Waters Medical Systems/zareba Systems |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| M0X100 PRIMARY | Zareba Systems Inc. Div Waters Medical Systems/zareba Systems (USA) |
NSN 6530-00-149-0125 is a Preservation System,kidney, manufactured by Zareba Systems Inc. Div Waters Medical Systems/zareba Systems, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.
NSN 6530-00-149-0125 has 1 manufacturer part number on file: M0X100 (Zareba Systems Inc. Div Waters Medical Systems/zareba Systems).
Key specifications for M0X100: Special Features: MOBILE,115 VOLT,60 HZ,AC; 920 WATTS; OVER-ALL DIM.;39 BY 21 BY 18 IN.; CABINET MOUNTED ON CASTERS; ALUMINUM CONTROL PANELS; WITH A STERILE,DISPOSABLE PLASTIC ORGAN CASSETTE WHICH INCLUDES A COMPLETE CIRCULATION SYSTEM WITH ORGAN CHAMBERS TO ACCOMODATE ONE OR TWO KIDNEYS,AND A SET OF TWO EACH SIZE 2 THROUGH 7 MM CANNULAS; W/HIGH TEMPERATURE ALARM SYSTEM,REFRIGERATION SYSTEM,VARIABLE PULSE RATE CONTROL,INDIVIDUAL ON-OFF CONTROLS FOR MASTER POWER,PULSATILE PUMP,COMPRESSOR,COOLANT CIRCULATORY PUMP,AND AIR BLOWERS; ORGAN CASSETTE MAY BE USED WITH PORTABLE PRESERVATION SYSTEM,6530-00-149-0126 IN THE FIELD,FOR USE IN MAINTAINING THE VIABILITY OF KIDNEYS PRIOR TO TRANSPLANTATION MM; Part Name Assigned by Controlling Agency: PRESERVATION SYSTEM KIDNEY MOBILE 115 VOLT 60 HERTZ AC 920W W. 0 specifications are documented in the U.S. Government catalog.