The Generator,x-Ray Apparatus,medica, cataloged under National Stock Number 6525-01-726-7487, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Minxray Inc. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6525-01-726-7487 |
| Primary Part Number | TR90BH |
| Item Name | Generator,x-Ray Apparatus,medica |
| FSC / FSG | 6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary |
| Manufacturer | Minxray Inc |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| TR90BH PRIMARY | Minxray Inc (USA) |
| Reference | Meaning |
|---|---|
| 6525NCM251210 | 5/1 Secondary reference Defense Medical Standardization Board |
| 1681519 | 5/1 Secondary reference U.S. Government activity |
NSN 6525-01-726-7487 is a Generator,x-Ray Apparatus,medica, manufactured by Minxray Inc, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.
NSN 6525-01-726-7487 has 1 manufacturer part number on file: TR90BH (Minxray Inc).
Key specifications for TR90BH: Special Features: BATTERY-POWERED, COMPUTER CONTROLLED HIGH FREQUENCY CONVERTER. X-RAY OUTPUT: 20-10MA AT 40-90KVDC, UNIQUE HIGH POWER MODE, INCLUDES QUICK CHANGE LITHIUM ION BATTERY, TIMER: 0.01-1.00 (+0.01+.30) 0.01 SEC STEPS, CETD D-0814M X--RAY TUBE, 0.8MM FOCAL SPOT, 9.86KHU (7KJ) ANODE HEAT STORAGE, TWO STAGE DEADMAN TYPE EXPOSURE SWITCH WITH RJ11 CONNECTOR, 8FT EXPOSURE CORD, COLLIMATOR: MIKASA MODEL R-300V THAT HAS CONTINUOUSLY ADJUSTABLE LIGHT BEAM TYPE WITH ADJUSTABLE LIGHT BEAM TYPE WITH ADJUSTABLE DUAL INTEGRATED LASER POINTERS TO INDICATE CENTRAL RAY & DISTANCE IN BRIGHT AMBIENT LIGHT CONDITIONS, TYPICAL USE PROVIDES 300-500 EXPOSURES PER CHARGE, ABILITY TO CHANGE BETWEEN MAS AND EXPOSURE TIME, LARGE TOUCH-PAD CONTROL, COLLIMATOR NOT INTERCONNECTED WITH X-RAY TUBE TO MINIMIZE SHOCK IF COLLIMATOR IS DAMAGED; LIGHTWEIGHT, ULTRA-DURABLE, AND POWERFUL WITH A LONG-LASTING BATTERY LIFE. V; Part Name Assigned by Controlling Agency: X-RAY GENERATOR, BATTERY-POWERED, PORTABLE; End Item Identification: NSN 6525017207557. 0 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.