The Ultrasonic Unit,diagnostic,human, cataloged under National Stock Number 6525-01-693-6226, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Fujifilm Sonosite Inc. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6525-01-693-6226 |
| Primary Part Number | P23561 |
| Item Name | Ultrasonic Unit,diagnostic,human |
| FSC / FSG | 6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary |
| Manufacturer | Fujifilm Sonosite Inc |
| Status | ACTIVE |
| Voltage in Volts and Current Type | 115.0 AC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| P23561 PRIMARY | Fujifilm Sonosite Inc (USA) |
| Reference | Meaning |
|---|---|
| 6525NCM206748 | 5/1 Secondary reference Defense Medical Standardization Board |
| 1588053 | 5/1 Secondary reference U.S. Government activity |
NSN 6525-01-693-6226 is a Ultrasonic Unit,diagnostic,human, manufactured by Fujifilm Sonosite Inc, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.
NSN 6525-01-693-6226 has 1 manufacturer part number on file: P23561 (Fujifilm Sonosite Inc).
Key specifications for P23561: Voltage in Volts and Current Type: 115.0 AC; Special Features: P23561 (EDGE II EMED ACUTE CARE CONFIGURATION). THE CONFIGURATION INCLUDES: SONOSITE EDGEII, COLOR APPLICATION SOFTWARE PACKAGE EDGEII, DICOM, ADVANCED OB CALULATIONS, STEEP NEEDLE PROFILING, RC60XI (ARMORED), HFL38X (ARMORED), STAND, TRIPLE TRANSDUCER CONNECT, UPX898 SONY B AND W DIGITAL AND ANALOG PRINTER, POWER PACK, POWERPARK, 2 SERVICE MANUALS AND USER GUIDE.; Part Name Assigned by Controlling Agency: EDGE II EMED ACUTE CARE ULTRASOUND CONFIGURATION. 1 specification is documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.