The X-Ray Apparatus,radiographic,med, cataloged under National Stock Number 6525-01-384-9296, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Picker Intl Inc. Government technical data includes 14 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6525-01-384-9296 |
| Primary Part Number | CLINIX VP4 |
| Item Name | X-Ray Apparatus,radiographic,med |
| FSC / FSG | 6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary |
| Manufacturer | Picker Intl Inc |
| Status | ACTIVE |
| Rectification Type | FULL-WAVE |
| Phase | THREE |
| Tube Cooling Method | AIR |
| Frequency in Hertz | 50.0 OR 60.0 |
| Tube Type | DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC |
| Radiographic Timer Type | EXPOSURE |
| Transformer Rectification Method | SELF-RECTIFYING |
| Tube Quantity | 1 |
| Tube Mounting Type | TUBE STAND |
| Tube Stand Mounting Type | BASE |
| Table Type | NONTILTING |
| Mounting Type | STATIONARY |
| Operation Method | AUTOMATIC |
| Transformer Output Capacity | 300 MA AT 125 KVP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| CLINIX VP4 PRIMARY | Picker Intl Inc (USA) |
| Reference | Meaning |
|---|---|
| LCR/OKS W/PROVISIONING | 5/1 Secondary reference Picker Intl Inc |
NSN 6525-01-384-9296 is a X-Ray Apparatus,radiographic,med, manufactured by Picker Intl Inc, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.
NSN 6525-01-384-9296 has 1 manufacturer part number on file: CLINIX VP4 (Picker Intl Inc).
Key specifications for CLINIX VP4: Rectification Type: FULL-WAVE; Phase: THREE; Tube Cooling Method: AIR; Frequency in Hertz: 50.0 OR 60.0. 14 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.