PartsTable TECHNICAL DATA SHEET
NSN 6525-01-345-6089Government record, cited

Processing Machine, Radiographic6525-01-345-6089

NSN 6525-01-345-6089 · NIIN 013456089
FSC 6525 — Imaging Equipment and Supplies: Medical, Dental, Veterinary · FSG 65 — Medical, Dental, and Veterinary Equipment
Government record, cited
Also searched as  6525-01-345-6089 · 6525013456089 · NIIN 013456089 · 01-345-6089 · FSC 6525 Imaging Equipment and Supplies: Medical, Dental, Veterinary · FZ3H2000 · CP1000 · CP1000 · FZ3H2000 · FZ3H2000
Nearby stock numbers  ·
Features
  • Processing Machine,radiographic — FSC 6525
  • Drive Type: BELT
  • Film Size Accommodated: 4 IN. BY 4 IN. THROUGH 14 IN. BY 36 IN. IN
  • Capacity: 2.50 LITERS TANK
  • Processing Speed: 3 MINUTES
  • Voltage in Volts: 110.0
  • Replenisher Solution Tank Quantity: 6
  • Integral Replenisher Solution Pump: INCLUDED
Identification
  • NSN: 6525-01-345-6089
  • NIIN: 013456089
  • FSC: 6525 — Imaging Equipment and Supplies: Medical, Dental, Veterinary
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
General Description

The Processing Machine,radiographic, cataloged under National Stock Number 6525-01-345-6089, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 10 specifications, cited from the U.S. Government catalog. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6525-01-345-6089
Item NameProcessing Machine,radiographic
FSC / FSG6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary
StatusACTIVE
Drive TypeBELT
Film Size Accommodated4 IN. BY 4 IN. THROUGH 14 IN. BY 36 IN. IN
Capacity2.50 LITERS TANK
Processing Speed3 MINUTES
Voltage in Volts110.0
Replenisher Solution Tank Quantity6
Integral Replenisher Solution PumpINCLUDED
Frequency Rating60.0 HERTZ NOMINAL
MaterialPLASTIC TANK
Furnished Items and QuantityREPLENISHER BOTTLES,6; FEED TRAYCOVER,1; OPERATOR'S MANUAL,1
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Unit of IssueEA
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6640-01-541-6664F148560 POSSIBLE MATCH
TIP,PIPET
Possible match (shared part number)Gilson, Inc. Dba Gilson Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
FZ3H2000 3/1 Design control — primary reference
Agfa Corporation Dba Agfa II Acquisition Corp
CP1000 5/1 Secondary reference
Agfa Corporation Dba Agfa II Acquisition Corp
CP1000 5/9 Secondary reference
Bayer Corp Agfa Div Medical Business Group
FZ3H2000 5/9 Secondary reference
Bayer Corporation
FZ3H2000 5/9 Secondary reference
Bayer Corp Agfa Div Medical Business Group
Related Parts
6640-01-541-6664POSSIBLE MATCH
TIP,PIPET
F148560

Frequently Asked Questions

What is NSN 6525-01-345-6089?

NSN 6525-01-345-6089 is a Processing Machine,radiographic, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.

What NSN replaces 6525-01-345-6089?

1 possible match (shared part number, not a government interchangeability claim): 6640-01-541-6664. Verify interchangeability with system specifications before substitution.

What are the specifications of 6525-01-345-6089?

Key specifications for 6525-01-345-6089: Overall Height: 17.000 INCHES NOMINAL IN; Drive Type: BELT; Film Size Accommodated: 4 IN. BY 4 IN. THROUGH 14 IN. BY 36 IN. IN; Capacity: 2.50 LITERS TANK. 10 specifications are documented in the U.S. Government catalog.

Is NSN 6525-01-345-6089 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com