The X-Ray Apparatus,radiographic and, cataloged under National Stock Number 6525-01-216-3378, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6525-01-216-3378 |
| Item Name | X-Ray Apparatus,radiographic and |
| FSC / FSG | 6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary |
| Status | ACTIVE |
| Rectification Type | FULL-WAVE |
| Phase | SINGLE |
| Frequency in Hertz | 50.0 OR 60.0 |
| Camera Type | HIGH RESOLUTION,ULTRA-LOW LIGHT LEVEL,TV |
| Tube Type | DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC AND DOUBLE FOCUS, ROTATING ANODE FLUOROSCOPIC |
| Design Type | MOBILE |
| Supplementary Features | SOLID STATE; TUBE MOUNTING C AND L ARM; IMAGE INTENSIFICATION SYSTEM; BEAM LIMITING DEVICE; SKIN SPACER; 500 WATTS STANDBY,1200 WATTS MAX |
| Voltage in Volts | 115.0 AND 230.0 |
| Transformer Rectification Method | SOLID STATE |
| Tube Quantity | 1 |
| Cassette Size | 9-1/2 IN. X 9-1/2 IN. MIN IN |
| Accessory Components and Quantity | SKIN SPACER,1 |
| Tube Mounting Type | MOVABLE C ARM AND MOVABLE L ARM |
| Tube Stand Mounting Type | BASE |
| Transformer Output Capacity | 30 MA AT 100 KVP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Reference | Meaning |
|---|---|
| G-338 | 3/1 Design control — primary reference Defense Medical Standardization Board |
NSN 6525-01-216-3378 is a X-Ray Apparatus,radiographic and, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.
Key specifications for 6525-01-216-3378: Rectification Type: FULL-WAVE; Phase: SINGLE; Frequency in Hertz: 50.0 OR 60.0; Camera Type: HIGH RESOLUTION,ULTRA-LOW LIGHT LEVEL,TV. 15 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.