The X-Ray Apparatus,radiographic,med, cataloged under National Stock Number 6525-01-200-5800, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Defense Medical Standardization Board. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6525-01-200-5800 |
| Primary Part Number | C/N4-671 |
| Item Name | X-Ray Apparatus,radiographic,med |
| FSC / FSG | 6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary |
| Manufacturer | Defense Medical Standardization Board |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| C/N4-671 PRIMARY | Defense Medical Standardization Board (USA) |
NSN 6525-01-200-5800 is a X-Ray Apparatus,radiographic,med, manufactured by Defense Medical Standardization Board, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.
NSN 6525-01-200-5800 has 1 manufacturer part number on file: C/N4-671 (Defense Medical Standardization Board).
Key specifications for C/N4-671: Special Features: 25-40 MA; 60-100 KVP; 115/230 VOLT; 50/60 HZ; AC: 4500 WATTS; ON WHEELS; IN REUSABLE CONTAINER; CAN BE UNPACKED, ASSEMBLED, AND MADE OPERATIONAL IN 10 MINUTES BY ONE TRAINED INDIVIDUAL; ASSEMBLY-DISASSEMBLY TOOLS PROVIDED; REQUIRES 75 IN. (190.5 CM) CEILING HEIGHT AND 32 DEG TO 100 DEG F (0 DEG TO 38 DEG C) AMBIENT TEMPERATURE WITH NOT MORE THAN 95 PCT RELATIVE HUMIDITY; CONTROL UNIT WITH ATTACHED CORD PERMITS OPERATOR TO BE AT LEAST 6 FT. (1.8 METER) FROM UNIT; FOR USE IN SMALL MEDICAL UNITS OUTSIDE FIELD TYPE HOSPITALS TO DETERMINE THE NATURE AND EXTENT OF INJURIES WHICH MAY HAVE TO BE EVACUATED TO HIGHER LEVEL FACILITIES; MAY ALSO BE USED TO MEET BEDSIDE RADIOGRAPHY REQUIREMENTS; COMPATIBLE WITH PEDESTAL TYPE OPERATING TABLES; FOR USE IN FIELD ASSEMBLIES AND OPERATING ROOMS; GENERIC MASTER ITEMS; FOR BRAND SPECIFIC END ITEM,SEE 6525-01-325-3740 CM; Part Name Assigned by Controlling Agency: X-RAY APPARATUS: LOW CAPACITY PORT. 0 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.