The Ultrasonic Unit,blood Flow Detec, cataloged under National Stock Number 6525-01-192-9456, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6525-01-192-9456 |
| Item Name | Ultrasonic Unit,blood Flow Detec |
| FSC / FSG | 6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Reference | Meaning |
|---|---|
| G-240 | 3/2 Design control — primary reference U.S. Government activity |
NSN 6525-01-192-9456 is a Ultrasonic Unit,blood Flow Detec, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 6140-01-464-9726. Verify interchangeability with system specifications before substitution.
Key specifications for 6525-01-192-9456: Special Features: D SHALL BE ELECTRICALLY SHIELDED FOR PATIENT/OPERATOR SAFETY AND OPERVENTION OF ELECTRICAL INTERFERENCE. (9) THE ELECTRICAL CHARACTERISTICS SHALL BE CONSISTENT WITH THE REQUIREMENTS OF THE LATEST EDITION OF SPECIFICATIONDPSC-DEPMEDS-AT (DM);SHALL BE PROVISIONED IN ACCORDANCE WITH THE REQUIREMENTS CATAINED IN THE LATEST EDITION OF SPECIFICATION DPSC-DEPMEDS-AT (DM);SHALL BE CAPABLE OF ASSESSING PATENCY OF VENEL GRAFTS INTRAOPERATIVELY BY VARYING AN AUBIBLE PITCH FREQUENCY AS BLOOD FLOW VELOCITY CHANGES; SHALL BE PROVIDED WITH AN 11.5 CM PENCIL PROBE;PROBE SHALL OPERATE AT A CONSTANT PRE-TUNED FREQUENCY OFAPPROX. 8MHZ MHz; Part Name Assigned by Controlling Agency: ULTRASONIC UNIT BLOOD FLOW DETECTION 120/230V 50/60HZ DOPPLER V. 0 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.