The X-Ray Apparatus,radiographic and, cataloged under National Stock Number 6525-01-130-4930, is classified within Federal Supply Class 6525 (Imaging Equipment and Supplies: Medical, Dental, Veterinary) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Onyx Medical Corporation. Government technical data includes 18 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6525-01-130-4930 |
| Primary Part Number | 1-1044F |
| Item Name | X-Ray Apparatus,radiographic and |
| FSC / FSG | 6525 / 65 — Imaging Equipment and Supplies: Medical, Dental, Veterinary |
| Manufacturer | Onyx Medical Corporation |
| Status | ACTIVE |
| Rectification Type | FULL-WAVE |
| Phase | SINGLE |
| Tube Cooling Method | AIR |
| Frequency in Hertz | 50.0 OR 60.0 |
| Tube Type | DOUBLE FOCUS, ROTATING ANODE FLUOROSCOPIC AND DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC |
| Design Type | STATIONARY |
| Drive Type | MOTOR |
| Supplementary Features | USE W/IMAGE INTENSIFIER; OVERHEAD TUBE MOUNT; VERTICAL CASSETTE HOLDER; FOR USE IN FIELD ASSY ONLY |
| Voltage in Volts | 190.0 AND 270.0 |
| Transformer Rectification Method | SELF-RECTIFYING |
| Tube Quantity | 2 |
| Accessory Components and Quantity | ADJUSTABLE NON-SKID FOOTREST 1; COMPRESSION-IMMOBILIZATION DEVICE 1; HEAD CLAMP 1; PATIENT GRASP HANDLES 1 PR; SKIDPROOF PATIENT STEP 1; SHOULD REST 1; UROLOGICAL KNEE CRUTCHES 1 PR |
| Tube Mounting Type | TABLE AND TUBE STAND |
| Tube Stand Mounting Type | FLOOR |
| Bucky Diaphragm | INCLUDED |
| Tilt Range | 90 DEGREES VERTICAL AND 15 DEGREES TRENDLEBERG |
| Table Type | TILTING |
| Transformer Output Capacity | TO 300 MA AT 150 KV PEAK |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 1-1044F PRIMARY | Onyx Medical Corporation (USA) |
NSN 6525-01-130-4930 is a X-Ray Apparatus,radiographic and, manufactured by Onyx Medical Corporation, classified under FSC 6525, Imaging Equipment and Supplies: Medical, Dental, Veterinary. Status: active.
NSN 6525-01-130-4930 has 1 manufacturer part number on file: 1-1044F (Onyx Medical Corporation).
Key specifications for 1-1044F: Rectification Type: FULL-WAVE; Phase: SINGLE; Tube Cooling Method: AIR; Frequency in Hertz: 50.0 OR 60.0. 18 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.