PartsTable TECHNICAL DATA SHEET
NSN 6515-01-733-5663Government record, cited

Transfer Set, Blood-Plasma6515-01-733-5663

NSN 6515-01-733-5663 · NIIN 017335663 · Part number A100754
Cardinal Health 200, Llc · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 07TA6
Government record, cited
NSN 6515-01-733-5663 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-733-5663. Manufacturer of record part number: A100754.
Also searched as  6515-01-733-5663 · 6515017335663 · NIIN 017335663 · 01-733-5663 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 07TA6 · A100754 · 6530NCM251930 · 1700157
Nearby stock numbers  ·
Features
  • Transfer Set,blood-Plasma — FSC 6515
  • 2 manufacturer part numbers on file
  • Manufacturer of record: Cardinal Health 200, Llc
Identification
  • NSN: 6515-01-733-5663
  • NIIN: 017335663
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: A100754
  • Manufacturer: Cardinal Health 200, Llc
General Description

The Transfer Set,blood-Plasma, cataloged under National Stock Number 6515-01-733-5663, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cardinal Health 200, Llc. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: CS.

Technical Specifications
ParameterValue
NSN6515-01-733-5663
Primary Part NumberA100754
Item NameTransfer Set,blood-Plasma
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerCardinal Health 200, Llc
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueCS
Cross-Reference Index
Part NumberManufacturer
A100754 Terumo Bct Inc Dba Caridianbct Inc (USA)
A100754 PRIMARY Cardinal Health 200, Llc (USA)
Reference documents
ReferenceMeaning
6530NCM251930 5/1 Secondary reference
Defense Medical Standardization Board
1700157 5/1 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-733-5663?

NSN 6515-01-733-5663 is a Transfer Set,blood-Plasma, manufactured by Cardinal Health 200, Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-733-5663?

NSN 6515-01-733-5663 has 2 manufacturer part numbers on file: A100754 (Terumo Bct Inc Dba Caridianbct Inc), A100754 (Cardinal Health 200, Llc).

What are the specifications of A100754?

Key specifications for A100754: Special Features: A HAND-HELD, MANUALLY OPERATED DEVICE INTENDED FOR SINGLE-USE TO OBTAIN A SPECIMEN OF BLOOD COMPONENTS (SPECIFICALLY DESIGNED FOR PLATELETS), OR BLOOD CULTURE FROM A SPECIMEN RECEPTACLE. FACILITATES ITS TRANSFER TO ANOTHER RECEPTACLE (E.G., EVACUATED BLOOD COLLECTION TUBE, CULTURE BOTTLE) FOR SUBSEQUENT ANALYSIS. INCLUDES A SPIKE/NEEDLE FOR SAMPLING THE SPECIMEN THROUGH THE SEALED STOPPER OF THE RECEPTACLE IN A CLOSED SYSTEM. DESIGNED WITH AN INTEGRATED SAFETY MECHANISM TO REDUCE THE RISK OF USER EXPOSURE TO THE SPECIMEN AND NEEDLE. 20ML SINGLE UNIT CHAMBER; 110'S; Part Name Assigned by Controlling Agency: BLOOD COLLECTION DEVICE, PLATELET, CLOSED SYSTEM, STERILE, 20ML, 110S.. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-733-5663 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com