PartsTable TECHNICAL DATA SHEET
NSN 6515-01-733-4032Government record, cited

Regulator, Pressure, Tracheal Tube6515-01-733-4032

NSN 6515-01-733-4032 · NIIN 017334032 · Part number HCSCUFF0041H
Medline Industries, Lp · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0PMN3
Government record, cited
NSN 6515-01-733-4032 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-733-4032. Manufacturer of record part number: HCSCUFF0041H.
Also searched as  6515-01-733-4032 · 6515017334032 · NIIN 017334032 · 01-733-4032 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 0PMN3 · HCSCUFF0041H · 6515NCM251901 · 1699893 · 991872
Nearby stock numbers  ·
Features
  • Regulator,pressure,tracheal Tube — FSC 6515
  • 2 manufacturer part numbers on file
  • Manufacturer of record: Medline Industries, Lp
Identification
  • NSN: 6515-01-733-4032
  • NIIN: 017334032
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: HCSCUFF0041H
  • Manufacturer: Medline Industries, Lp
General Description

The Regulator,pressure,tracheal Tube, cataloged under National Stock Number 6515-01-733-4032, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Medline Industries, Lp. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-733-4032
Primary Part NumberHCSCUFF0041H
Item NameRegulator,pressure,tracheal Tube
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerMedline Industries, Lp
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
HCSCUFF0041H PRIMARY Medline Industries, Lp (USA)
991872 Altitude Technologies Inc. Dba Chinook Medical Gear (USA)
Reference documents
ReferenceMeaning
6515NCM251901 5/1 Secondary reference
Defense Medical Standardization Board
1699893 5/1 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-733-4032?

NSN 6515-01-733-4032 is a Regulator,pressure,tracheal Tube, manufactured by Medline Industries, Lp, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-733-4032?

NSN 6515-01-733-4032 has 2 manufacturer part numbers on file: HCSCUFF0041H (Medline Industries, Lp), 991872 (Altitude Technologies Inc. Dba Chinook Medical Gear).

What are the specifications of HCSCUFF0041H?

Key specifications for HCSCUFF0041H: Special Features: THE MANOMETER IS A DISPOSABLE, BATTERY-POWERED, HAND-HELD, SYRINGE-LIKE DEVICE DESIGNED TO MEASURE AND MANUALLY REGULATE INTRA-CUFF PRESSURE IN ENDOTRACHEAL, TRACHEOTOMY, AND LARYNGEAL MASK AIRWAY (LMA) TUBES. FEATURING AN EMBEDDED PRESSURE GAUGE, IT IS FOR SINGLE-PATIENT USE, LIMITED TO 100 OPERATIONS, AND CAN BE CLEANED WITH DISINFECTANT. FILL VOLUME: 10 CC; MEASUREMENT RANGE: 0-99 CMH2O. UMDNS 16864 MANOMETER SETS. NON-REPLACEABLE LITHIUM COIN CELL BATTERY.; Part Name Assigned by Controlling Agency: SYRINGE, CUFF PRESSURE, REGULATING, BATTERY OPERATED (CUFFILL). 0 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-733-4032 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com