The Syringe and Needle,hypodermic, cataloged under National Stock Number 6515-01-718-6328, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Becton, Dickinson and Co Dba Becton Dickinson & Co. Government technical data includes 7 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: CS.
| Parameter | Value |
|---|---|
| NSN | 6515-01-718-6328 |
| Primary Part Number | 305782 |
| Item Name | Syringe and Needle,hypodermic |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Becton, Dickinson and Co Dba Becton Dickinson & Co |
| Status | ACTIVE |
| Needle Hub | PROVIDED |
| Plunger Thumb Rest Type | BUTTON |
| Capacity | 3.00 MILLILITERS |
| Cannula Length | 1.0 INCHES NOMINAL IN |
| Needle Gage Number | 22 |
| Features Provided | DISPOSABLE AND STERILE |
| Scale Type | SINGLE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | CS |
| Part Number | Manufacturer |
|---|---|
| 305782 PRIMARY | Becton, Dickinson and Co Dba Becton Dickinson & Co (USA) |
| BT305782 | Cardinal Health, Inc. (USA) |
| Reference | Meaning |
|---|---|
| 6515NCM249646 | 5/1 Secondary reference Defense Medical Standardization Board |
| 1664512 | 5/1 Secondary reference U.S. Government activity |
NSN 6515-01-718-6328 is a Syringe and Needle,hypodermic, manufactured by Becton, Dickinson and Co Dba Becton Dickinson & Co, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-718-6328 has 2 manufacturer part numbers on file: 305782 (Becton, Dickinson and Co Dba Becton Dickinson & Co), BT305782 (Cardinal Health, Inc.).
Key specifications for 305782: Needle Hub: PROVIDED; Plunger Thumb Rest Type: BUTTON; Capacity: 3.00 MILLILITERS; Cannula Length: 1.0 INCHES NOMINAL IN. 7 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.