The Blood-Fluid Warmer System, cataloged under National Stock Number 6515-01-710-8513, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Emit Corporation. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-710-8513 |
| Primary Part Number | FG100005 |
| Item Name | Blood-Fluid Warmer System |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Emit Corporation |
| Status | ACTIVE |
| Features Provided | DISPOSABLE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| FG100005 PRIMARY | Emit Corporation (USA) |
| HYPOTHERMX-LG | First Nation Group Llc (USA) |
| Reference | Meaning |
|---|---|
| 6515NCM239082 | 5/1 Secondary reference Defense Medical Standardization Board |
| 1652671 | 5/1 Secondary reference U.S. Government activity |
NSN 6515-01-710-8513 is a Blood-Fluid Warmer System, manufactured by Emit Corporation, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-710-8513 has 2 manufacturer part numbers on file: FG100005 (Emit Corporation), HYPOTHERMX-LG (First Nation Group Llc).
Key specifications for FG100005: Features Provided: DISPOSABLE; Special Features: LIGHT WEIGHT(1 LBS), PORTABLE, ACUTE (1 HOURS CONTINUOUS USE) SOLUTION TO OFFER ACTUAL THERAPEUTIC WARMING IN THE FIELD FOR INJURED PATIENTS; CAPABLE OF WARMING UP TO 2 LITERS OF SALINE INTRODUCED AT 15C AND 2 UNITS OF PACKED RED BLOOD CELLS INTRODUCED AT 5C TO 38C +/- 3C WITH AN INFUSION RATE BETWEEN 50 ML/MIN AND 100 ML/MIN AND AMBIENT CONDITIONS BETWEEN 0C AND 40C; POWER SOURCE: LITHIUM SULFUR DIOXIDE BATTERY; DIMENSIONS: 7IN X 3IN X 1.5IN. LBS; Part Name Assigned by Controlling Agency: BLOOD-FLUID WARMER, LIGHT WEIGHT, PORTABLE. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.