PartsTable TECHNICAL DATA SHEET
NSN 6515-01-702-4825Government record, cited

Needle and Guard, Hypodermic6515-01-702-4825

NSN 6515-01-702-4825 · NIIN 017024825 · Part number 8881850515
Cardinal Health 200, Llc · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 07TA6
Government record, cited
NSN 6515-01-702-4825 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-702-4825. Manufacturer of record part number: 8881850515.
Also searched as  6515-01-702-4825 · 6515017024825 · NIIN 017024825 · 01-702-4825 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 07TA6 · 8881850515 · 1629169 · 6515NCM227956
Nearby stock numbers  ·
Features
  • Needle and Guard,hypodermic — FSC 6515
  • Sterility: STERILE
  • Disposition After Initial Use: DISPOSABLE
  • 1 manufacturer part number on file
  • Manufacturer of record: Cardinal Health 200, Llc
Identification
  • NSN: 6515-01-702-4825
  • NIIN: 017024825
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 8881850515
  • Manufacturer: Cardinal Health 200, Llc
General Description

The Needle and Guard,hypodermic, cataloged under National Stock Number 6515-01-702-4825, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cardinal Health 200, Llc. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: CS.

Technical Specifications
ParameterValue
NSN6515-01-702-4825
Primary Part Number8881850515
Item NameNeedle and Guard,hypodermic
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerCardinal Health 200, Llc
StatusACTIVE
SterilitySTERILE
Disposition After Initial UseDISPOSABLE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueCS
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6515-01-724-3987 POSSIBLE MATCH
NEEDLE AND GUARD,HYPODERMIC
Possible match (shared part number)
Cross-Reference Index
Part NumberManufacturer
8881850515 PRIMARY Cardinal Health 200, Llc (USA)
Reference documents
ReferenceMeaning
1629169 5/1 Secondary reference
U.S. Government activity
6515NCM227956 5/1 Secondary reference
Defense Medical Standardization Board
Related Parts
6515-01-724-3987POSSIBLE MATCH
NEEDLE AND GUARD,HYPODERMIC

Frequently Asked Questions

What is NSN 6515-01-702-4825?

NSN 6515-01-702-4825 is a Needle and Guard,hypodermic, manufactured by Cardinal Health 200, Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-702-4825?

NSN 6515-01-702-4825 has 1 manufacturer part number on file: 8881850515 (Cardinal Health 200, Llc).

What NSN replaces 6515-01-702-4825?

1 possible match (shared part number, not a government interchangeability claim): 6515-01-724-3987. Verify interchangeability with system specifications before substitution.

What are the specifications of 8881850515?

Key specifications for 8881850515: Sterility: STERILE; Overall Length: 1.5 INCHES NOMINAL IN; Disposition After Initial Use: DISPOSABLE; Special Features: MONOJECT SAFETY SLIDING HYPODERMIC NEEDLE 25GA 1/2IN PLASTIC HUB. ONE-HANDED SAFETY ACTIVATION VIA MULTIPLE METHODS (FINGER, THUMB, OR SURFACE) FOR CLINICAL FLEXIBILITY. ROBUST SAFETY SHIELD ENCASES ENTIRE NEEDLE CANNULA FOR ENHANCED PROTECTION. AUDIBLE AND TACTILE "CLICK" CONFIRMS SAFETY DEVICE HAS BEEN ACTIVATED. BEVEL ORIENTATION, SELF-LEVELING NEEDLE SHEATH, ISO COLOR-CODED HUB, FULL RANGE OF GAUGES AND LENGTHS. STERILE, DISPOSABLE, NOT MADE WITH NATURAL RUBBER LATEX. IN. 2 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-702-4825 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com