PartsTable TECHNICAL DATA SHEET
NSN 6515-01-696-5384Government record, cited

Respirometer6515-01-696-5384

NSN 6515-01-696-5384 · NIIN 016965384 · Part number 00-295
Anesthesia Associates, Inc Div Ainca · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 63616
Government record, cited
NSN 6515-01-696-5384 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-696-5384. Manufacturer of record part number: 00-295.
Also searched as  6515-01-696-5384 · 6515016965384 · NIIN 016965384 · 01-696-5384 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 63616 · 00-295 · 6515NCM217252 · 1585156
Nearby stock numbers  ·
Features
  • Respirometer — FSC 6515
  • Disposition After Initial Use: REUSABLE
  • 1 manufacturer part number on file
  • Manufacturer of record: Anesthesia Associates, Inc Div Ainca
Identification
  • NSN: 6515-01-696-5384
  • NIIN: 016965384
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 00-295
  • Manufacturer: Anesthesia Associates, Inc Div Ainca
General Description

The Respirometer, cataloged under National Stock Number 6515-01-696-5384, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Anesthesia Associates, Inc Div Ainca. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-696-5384
Primary Part Number00-295
Item NameRespirometer
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerAnesthesia Associates, Inc Div Ainca
StatusACTIVE
Disposition After Initial UseREUSABLE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
00-295 PRIMARY Anesthesia Associates, Inc Div Ainca (USA)
Reference documents
ReferenceMeaning
6515NCM217252 5/1 Secondary reference
Defense Medical Standardization Board
1585156 5/1 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-696-5384?

NSN 6515-01-696-5384 is a Respirometer, manufactured by Anesthesia Associates, Inc Div Ainca, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-696-5384?

NSN 6515-01-696-5384 has 1 manufacturer part number on file: 00-295 (Anesthesia Associates, Inc Div Ainca).

What are the specifications of 00-295?

Key specifications for 00-295: Disposition After Initial Use: REUSABLE; Special Features: RESPIROMETER; DIGITAL; WRIGHT, W/ SENSOR; CONTROLLER; 22MMFX22MMF ADAPTER; RANGE: 0-200 LITERS; POWER SOURCE: 9V BATTERY, INTERNAL, INCLUDED; MEASUREMENT TYPE: AIR/GAS VOLUME FLOW; MEASUREMENT DIRECTION: INLET TO OUTLET ONLY TYPICAL RESPIRATORY USE: TIDAL VOLUME, MINUTE VOLUME, VOLUME FLOW RATE: 5 LPM MINIMUM, 150 LPM MAXIMUM; RESOLUTION: 0.02 LITER ACCURACY: +/- 2% AT 15 LPM CONSTANT-FLOW CALIBRATION POINT RESISTANCE TO FLOW: 2 CMH2O BACKPRESSURE AT 100 LPM INLET CONNECTION SIZE: 22MM MALE ISO TAPER OUTLET CONNECTION SIZE: 22MMMALE ISO TAPER. ACCESSORY: REPLACEMENTS CONTROL UNIT P/N 00-294, SENSING UNIT P/N 00-299, (CONTROLLER TO SENSOR) DOUBLE PLUG P/N 00-303, RETRACTILE CABLE, 6 FOOT P/N 00-296, POLE CLAMP 1 MAX D. V; Part Name Assigned by Controlling Agency: RESPIROMETER, ELECTRONIC DIGITAL. 1 specification is documented in the U.S. Government catalog.

Is NSN 6515-01-696-5384 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com