The Catheter,arterial Embolectomy, cataloged under National Stock Number 6515-01-693-2791, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Edwards Lifesciences Llc. Government technical data includes 4 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: PG.
| Parameter | Value |
|---|---|
| NSN | 6515-01-693-2791 |
| Primary Part Number | 120806FP |
| Item Name | Catheter,arterial Embolectomy |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Edwards Lifesciences Llc |
| Status | ACTIVE |
| Design Designation | FOGARTY |
| Unit Package Quantity | 5 |
| Nominal Diameter | 6.0 FRENCH |
| Balloon Capacity | 2.0 MILLILITERS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | PG |
| Part Number | Manufacturer |
|---|---|
| 120806FP PRIMARY | Edwards Lifesciences Llc (USA) |
| 120806FP | Cardinal Health 200, Llc (USA) |
| Reference | Meaning |
|---|---|
| 6515NCM216818 | 5/1 Secondary reference Defense Medical Standardization Board |
| 1589545 | 5/1 Secondary reference U.S. Government activity |
NSN 6515-01-693-2791 is a Catheter,arterial Embolectomy, manufactured by Edwards Lifesciences Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-693-2791 has 2 manufacturer part numbers on file: 120806FP (Edwards Lifesciences Llc), 120806FP (Cardinal Health 200, Llc).
Key specifications for 120806FP: Design Designation: FOGARTY; Unit Package Quantity: 5; Nominal Diameter: 6.0 FRENCH; Special Features: LENGTH OF 80 CM; CATHETER SIZE 6F; INFLATED BALLOON DIAMETER 13 MM; MAX SIZE OF DEFLATED BALLOON 7.0 F; PACKAGE OF 5; USED FOR REMOVAL OF FRESH, SOFT EMBOLI AND THROMBI FROM VESSELS IN THE ARTERIES OF THE NON-CENTRAL CIRCULATORY SYSTEM; HAND-TIED USING A RECESSED WINDING TECHNIQUE TO SECURE BALLOON TO CATHETER; BALLOON EXHIBITS A SYMMETRY THAT EXERTS UNIFORM CONTACT WITH VESSEL WALLS FOR EVEN PRESSURE AND PRECISE TRACTION; ROUNDED TIP PROMOTES EASY INSERTION FOR REDUCED TRAUMA. MM. 4 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.