PartsTable TECHNICAL DATA SHEET
NSN 6515-01-681-3507Government record, cited

Stent, Arterial, Endoprosthesis6515-01-681-3507

NSN 6515-01-681-3507 · NIIN 016813507 · Part number VBJR060502A
Era Health Llc Div Veteran's Health Medical Supply · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 4MG27
Government record, cited
NSN 6515-01-681-3507 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-681-3507. Manufacturer of record part number: VBJR060502A.
Also searched as  6515-01-681-3507 · 6515016813507 · NIIN 016813507 · 01-681-3507 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 4MG27 · VBJR060502A · 6515NCM194733 · GORE VIABAHN · 1545725
Nearby stock numbers  ·
Features
  • Stent,arterial,endoprosthesis — FSC 6515
  • 1 manufacturer part number on file
  • Manufacturer of record: Era Health Llc Div Veteran's Health Medical Supply
Identification
  • NSN: 6515-01-681-3507
  • NIIN: 016813507
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: VBJR060502A
  • Manufacturer: Era Health Llc Div Veteran's Health Medical Supply
General Description

The Stent,arterial,endoprosthesis, cataloged under National Stock Number 6515-01-681-3507, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Era Health Llc Div Veteran's Health Medical Supply. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-681-3507
Primary Part NumberVBJR060502A
Item NameStent,arterial,endoprosthesis
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerEra Health Llc Div Veteran's Health Medical Supply
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6515-01-681-3512 POSSIBLE MATCH
STENT,ARTERIAL,ENDOPROSTHESIS
Possible match (shared part number)
Cross-Reference Index
Part NumberManufacturer
VBJR060502A Era Health Llc Div Veteran's Health Medical Supply (USA)
Reference documents
ReferenceMeaning
6515NCM194733 5/1 Secondary reference
Defense Medical Standardization Board
VBJR060502A 3/9 Design control — primary reference
Wl Gore & Associates Inc
GORE VIABAHN 5/9 Secondary reference
Wl Gore & Associates Inc
1545725 5/1 Secondary reference
U.S. Government activity
Related Parts
6515-01-681-3512POSSIBLE MATCH
STENT,ARTERIAL,ENDOPROSTHESIS

Frequently Asked Questions

What is NSN 6515-01-681-3507?

NSN 6515-01-681-3507 is a Stent,arterial,endoprosthesis, manufactured by Era Health Llc Div Veteran's Health Medical Supply, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-681-3507?

NSN 6515-01-681-3507 has 1 manufacturer part number on file: VBJR060502A (Era Health Llc Div Veteran's Health Medical Supply).

What NSN replaces 6515-01-681-3507?

1 possible match (shared part number, not a government interchangeability claim): 6515-01-681-3512. Verify interchangeability with system specifications before substitution.

What are the specifications of VBJR060502A?

Key specifications for VBJR060502A: Special Features: STENT, ARTERIAL, ENDOPROSTHESIS VIABAHN 6 MM X 5 CM, 120 CM, 6 FR PROFILE, HEPARIN BIOACTIVE SURFACE, STERILE, SINGLE USE ONLY. MM; Part Name Assigned by Controlling Agency: STENT, ARTERIAL, ENDOPROSTHESIS VIABAHN 6MM X 5 CM, 120 CM, 6 FR MM. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-681-3507 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com