The Injector,intraosseous Needle, cataloged under National Stock Number 6515-01-667-2884, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Combat Medical Systems Llc. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-667-2884 |
| Primary Part Number | NIO+ |
| Item Name | Injector,intraosseous Needle |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Combat Medical Systems Llc |
| Status | ACTIVE |
| Shape | T |
| Disposition After Initial Use | DISPOSABLE |
| End Type | OLIVARY |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| NIO+ PRIMARY | Combat Medical Systems Llc (USA) |
| Reference | Meaning |
|---|---|
| 1599221 | 5/1 Secondary reference U.S. Government activity |
| 6515NCM217244 | 5/1 Secondary reference Defense Medical Standardization Board |
| NIO-A | 5/9 Secondary reference O.m. Performance, Inc. Dba Persys Medical Div Persys Medical |
NSN 6515-01-667-2884 is a Injector,intraosseous Needle, manufactured by Combat Medical Systems Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-667-2884 has 1 manufacturer part number on file: NIO+ (Combat Medical Systems Llc).
Key specifications for NIO+: Shape: T; Disposition After Initial Use: DISPOSABLE; Special Features: INTRAOSSEOUS DEVICE FOR GAINING IMMEDIATE VASCULAR ACCESS IN ADULT PATIENTS; STERILE, SINGLE-USE DEVICE, ELIMINATES THE RISK OF CROSS-CONTAMINATION; SAFE, NO EXPOSED NEEDLE; PATIENT-FRIENDLY AND USER-FRIENDLY; NO ASSEMBLY REQUIRED; NO EXTERNAL POWER SOURCE OR BATTERY REQUIRED; POCKET-SIZED AND LIGHTWEIGHT 3.5OZ; INDIVIDUALLY PACKED IN A RUGGEDIZED CASE; SEMI-AUTOMATIC; NEEDLE PENETRATION DEPTH: 25MM; SHELF LIFE: 5 YEARS. OZ; Part Name Assigned by Controlling Agency: NEW INTRAOSSEOUS DEVICE AUTO INJECT ADULT, DISPOSABLE, 15G G. 3 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.