PartsTable TECHNICAL DATA SHEET
NSN 6515-01-657-5229Government record, cited

Cannula, Catheter Needle6515-01-657-5229

NSN 6515-01-657-5229 · NIIN 016575229 · Part number G09490
Cook Medical Llc · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 393H0
Government record, cited
NSN 6515-01-657-5229 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-657-5229. Manufacturer of record part number: G09490.
Also searched as  6515-01-657-5229 · 6515016575229 · NIIN 016575229 · 01-657-5229 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 393H0 · G09490 · 1425081 · 6515NCM163075
Nearby stock numbers  ·
Features
  • Cannula,catheter Needle — FSC 6515
  • 1 manufacturer part number on file
  • Manufacturer of record: Cook Medical Llc
Identification
  • NSN: 6515-01-657-5229
  • NIIN: 016575229
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: G09490
  • Manufacturer: Cook Medical Llc
General Description

The Cannula,catheter Needle, cataloged under National Stock Number 6515-01-657-5229, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cook Medical Llc. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-657-5229
Primary Part NumberG09490
Item NameCannula,catheter Needle
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerCook Medical Llc
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6515-01-658-97478300-0800-01 POSSIBLE MATCH
LEAD SET,ELECTRODE,ELECTROCARDIO
Possible match (shared part number)Zoll Medical Corporation Dba Zoll
Cross-Reference Index
Part NumberManufacturer
G09490 PRIMARY Cook Medical Llc (USA)
Reference documents
ReferenceMeaning
1425081 5/1 Secondary reference
U.S. Government activity
6515NCM163075 5/1 Secondary reference
Defense Medical Standardization Board
Related Parts
6515-01-658-9747POSSIBLE MATCH
LEAD SET,ELECTRODE,ELECTROCARDIO
8300-0800-01

Frequently Asked Questions

What is NSN 6515-01-657-5229?

NSN 6515-01-657-5229 is a Cannula,catheter Needle, manufactured by Cook Medical Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-657-5229?

NSN 6515-01-657-5229 has 1 manufacturer part number on file: G09490 (Cook Medical Llc).

What NSN replaces 6515-01-657-5229?

1 possible match (shared part number, not a government interchangeability claim): 6515-01-658-9747. Verify interchangeability with system specifications before substitution.

What are the specifications of G09490?

Key specifications for G09490: Overall Length: 8.00 INCHES NOMINAL IN; Special Features: USED FOR PERCUTANEOUS FLUID ASPIRATIONS; HOLLOW STYLET NEEDLE DESIGN PERMITS ASPIRATION OF FLUID PRIOR TO STYLET REMOVAL; FOUR SIDE PORTS LOCATED ON THE DISTAL TIP OF THE CATHETER FACILITATE DRAINAGE WITHIN SMALL CAVITIES; SUPPLIED STERILE IN PEEL-OPEN PACKAGES; INTENDED FOR ONE-TIME USE; REF P/N: DTVN-5.0-19-10.0-YUEH CATHETER FR: 5, CATHETER LENGTH(CM): 10, NEEDLE GAGE: 19 DIM(IN): L8.0 X W4.0 X H 0.25; Part Name Assigned by Controlling Agency: YUEH CENTESIS CATHETER NEEDLES, 10CM CM. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-657-5229 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com