The Ventilator,volume,portable, cataloged under National Stock Number 6515-01-655-3181, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Automedx, Llc. Government technical data includes 5 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 5 manufacturers, enabling identification through both NSN and commercial part number lookups. 3 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6515-01-655-3181 |
| Primary Part Number | 70100-US-H |
| Item Name | Ventilator,volume,portable |
| FSC / FSG | 6515 / 65 — No Item Name Available |
| Manufacturer | Automedx, Llc |
| Status | ACTIVE |
| Voltage in Volts | 100.0 AND -240.0 |
| Frequency in Hertz | 50.0 OR -60.0 |
| Current Type | AC |
| Portability | PORTABLE |
| Universal Medical Device Nomenclature System Code | 18098 |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 6515NCM162861 | Defense Medical Standardization Board (USA) |
| 25-205 | Combat Medical Systems Llc (USA) |
| 1410597 | Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA) |
| 70100-US-H PRIMARY | Automedx, Llc (USA) |
| 25-205-MU | Equipement Des Metiers De La Defense - Emd (FRA) |
NSN 6515-01-655-3181 is a Ventilator,volume,portable, manufactured by Automedx, Llc, classified under FSC 6515 (No Item Name Available). Status: active.
NSN 6515-01-655-3181 has 5 cross-referenced part numbers: 6515NCM162861 (Defense Medical Standardization Board), 25-205 (Combat Medical Systems Llc), 1410597 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia), 70100-US-H (Automedx, Llc), 25-205-MU (Equipement Des Metiers De La Defense - Emd).
There are 3 known substitutes for 6515-01-655-3181: 4720-01-158-4041, 1630-01-342-0546, 6685-01-632-6096. Verify interchangeability with system specifications before substitution.
Key specifications for 70100-US-H: Voltage in Volts: 100.0 AND -240.0; Overall Width: 7.00 INCHES NOMINAL IN; Special Features: PORTABLE VENTILATOR; PROVIDES ASSISTED VENTILATION FOR UP TO 10 HOURS; SELECT THE HEIGHT OF THE PATIENT AND THE DEVICE DIALS IN A LUNG PROTECTIVE ARDSNET PROTOCOL TIDAL VOLUME BASED ON THE IDEAL BODY WEIGHT OF THE PATIENT; HANDS-FREE BAGGING DURING EVACUATION; ACCEPTS SUPPLEMENTAL O2, COMPRESSES OXYGEN NOT REQUIRED; FAIL-SAFE MECHANISMS AND VISUAL/AUDIBLE ALARMS; POWERED BY RECHARGEABLE LITHIUM BATTERY OR ELECTRICAL OUTLET; INCLUDES (1) EACH OF THE FOLLOWING COMPONENTS: VENTILATOR, HARD CASE, NOISE ATTENUATOR, CHARGER (TWO PIECE), O2 RESERVOIR, PATIENT BREATHING CIRCUIT, PATIENT MASK, HEAD STRAP, 20 ML SYRINGE, OPERATOR'S MANUAL; UNIT OF ISSUE EACH; WEIGHT 9.65 LBS; DIMENSIONS: 16.0 IN H BY 14.0 IN WIDE BY 7.0 IN DIA; POWER REQUIREMENTS: 100-240 VAC, 16.8VDC, 50-60 HZ; STORED AND TRANSPORTED IN HARD CASE; SHELF-LIFE: 5 YEARS, LATEX FREE; PRODUCT DEVICE CODE, 17423 VDC; Frequency in Hertz: 50.0 OR -60.0. 10 total characteristics are documented in the Federal Logistics Information System.