The Blood-Fluid Warmer System, cataloged under National Stock Number 6515-01-631-8735, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Vyaire Medical Inc Div Vyaire Respiratory Diagnostics Llc. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-631-8735 |
| Primary Part Number | 980105VS |
| Item Name | Blood-Fluid Warmer System |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Vyaire Medical Inc Div Vyaire Respiratory Diagnostics Llc |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 980105VS PRIMARY | Vyaire Medical Inc Div Vyaire Respiratory Diagnostics Llc (USA) |
| Reference | Meaning |
|---|---|
| 1223250 | 5/1 Secondary reference U.S. Government activity |
| 980105VS | 5/9 Secondary reference Carefusion 2200 Inc |
| 6515NCM141506 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6515-01-631-8735 is a Blood-Fluid Warmer System, manufactured by Vyaire Medical Inc Div Vyaire Respiratory Diagnostics Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-631-8735 has 1 manufacturer part number on file: 980105VS (Vyaire Medical Inc Div Vyaire Respiratory Diagnostics Llc).
Key specifications for 980105VS: Special Features: WARMER IS DESIGNED TO WORK IN CONJUNCTION WITH THE DISPOSABLE CARTRIDGE TO WARM IV FLUIDS; DESIGN OF THE WARMER ALLOWS IT TO BE PLACED WITHIN INCHES OF THE IV SITE; THIS PROXIMITY REDUCES THE POTENTIAL FOR FLUID COOLING WITHIN THE IV LINE; UNIT USES DRY-HEAT TECHNOLOGY TO ATTAIN A TEMPERATURE OF 40 DEG C +/- 2 DEG C; LIGHTWEIGHT AND TRANSPORTABLE; WEIGHT: 9.5 OZ. (275 G); DIMENSIONS: 5.0 IN. L X 2.6 IN. W X 1.2 IN. H; INPUT VOLTAGE: 28 VDC AT A MAXIMUM OF 300 WATTS VDC; Part Name Assigned by Controlling Agency: WARMER BLOOD AND FLUID ENFLOW IV. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.