PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

4922-9-940SFixation Set,external,orthopedic

Howmedica Osteonics Corp Dba Stryker Orthopaedics · NSN 6515-01-609-7248 · FSC 6515 · No Item Name Available
Verified by PartsTable
NSN 6515-01-609-7248 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-609-7248. Primary manufacturer part number: 4922-9-940S.
Features
  • Fixation Set,external,orthopedic — FSC 6515
  • 5 verified cross-references
  • Primary manufacturer: Howmedica Osteonics Corp Dba Stryker Orthopaedics
Applications
  • Industrial maintenance and repair
  • Government and military logistics
  • Equipment overhaul and refurbishment
General Description

The Fixation Set,external,orthopedic, cataloged under National Stock Number 6515-01-609-7248, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Howmedica Osteonics Corp Dba Stryker Orthopaedics. This item has 5 commercial cross-references from 5 manufacturers, enabling identification through both NSN and commercial part number lookups. 9 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-609-7248
Primary Part Number4922-9-940S
Item NameFixation Set,external,orthopedic
FSC / FSG6515 / 65 — No Item Name Available
ManufacturerHowmedica Osteonics Corp Dba Stryker Orthopaedics
StatusCANCELLED
Lifecycle & Compliance
Acquisition StatusCANCELLED
HAZMATNo
Unit of IssueEA
Verified Substitutes 9
No Item Name Available
5950-00-280-459831470 INTERCHANGEABLE
Transformer,power Autotransforme
Raytheon Company Dba Raytheon
5940-00-581-481231470 INTERCHANGEABLE
Terminal,lug
Te Connectivity Corporation
5998-00-985-0944 INTERCHANGEABLE
Circuit Card Assembly
3455-01-029-84201-1741-1000 INTERCHANGEABLE
Cutter,milling,end
New York Twist Drill Inc
5310-01-150-484631470 INTERCHANGEABLE
Washer,flat
Barnes Group Inc. Dba Barnes Distribution
4820-01-187-711150764 INTERCHANGEABLE
Parts Kit,valve
Jetstream of Houston, Llp Dba Jetstream of Houston Llp
3110-01-214-512132-31465 ITEM 5 INTERCHANGEABLE
Plate,retaining,bearing
Moog Inc. Dba Ampac-Isp Corp
6515-01-514-278031470 INTERCHANGEABLE
Gloves,surgeons'
Molnlycke Health Care Us, Llc Dba Molnlycke Health Care Us Div Molnlycke Health Care
Cross-Reference Index
Part NumberManufacturer
4922-9-940S Stryker Australia Pty Ltd (AUS)
31470 Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA)
4922-9-940S Saab Australia Pty Ltd (AUS)
6515NCM127765 Defense Medical Standardization Board (USA)
4922-9-940S PRIMARY Howmedica Osteonics Corp Dba Stryker Orthopaedics (USA)
Related Parts
6515-01-546-0559SUCCESSOR
NO ITEM NAME AVAILABLE
5950-00-280-4598INTERCHANGEABLE
TRANSFORMER,POWER AUTOTRANSFORME
31470
5940-00-581-4812INTERCHANGEABLE
TERMINAL,LUG
31470
5998-00-985-0944INTERCHANGEABLE
CIRCUIT CARD ASSEMBLY
3455-01-029-8420INTERCHANGEABLE
CUTTER,MILLING,END
1-1741-1000
5310-01-150-4846INTERCHANGEABLE
WASHER,FLAT
31470
4820-01-187-7111INTERCHANGEABLE
PARTS KIT,VALVE
50764
3110-01-214-5121INTERCHANGEABLE
PLATE,RETAINING,BEARING
32-31465 ITEM 5
6515-01-514-2780INTERCHANGEABLE
GLOVES,SURGEONS'
31470

Frequently Asked Questions

What is NSN 6515-01-609-7248?

NSN 6515-01-609-7248 is a Fixation Set,external,orthopedic, manufactured by Howmedica Osteonics Corp Dba Stryker Orthopaedics, classified under FSC 6515 (No Item Name Available). Status: cancelled.

What are the part numbers for NSN 6515-01-609-7248?

NSN 6515-01-609-7248 has 5 cross-referenced part numbers: 4922-9-940S (Stryker Australia Pty Ltd), 31470 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia), 4922-9-940S (Saab Australia Pty Ltd), 6515NCM127765 (Defense Medical Standardization Board), 4922-9-940S (Howmedica Osteonics Corp Dba Stryker Orthopaedics).

What NSN replaces 6515-01-609-7248?

There are 9 known substitutes for 6515-01-609-7248: 6515-01-546-0559, 5950-00-280-4598, 5940-00-581-4812 and 6 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 4922-9-940S?

Key specifications for 4922-9-940S: Special Features: FORWARD DEPLOYED FIELD PACK FIXATOR; STERILE; SELF-DRILLING, SELF-TAPPING APEX PINS; APPLICATIONS: TIBIA, FEMUR, HUMERUS, WRIST, OR PELVIC FRACTURES; FOR TEMPORARY STABILIZATION AND TRANSPORTATION ONLY; INCLUDES: (2)DELTA ROD TO ROD COUPLINGS NSN 6515-01-600-4116, (2)5-HOLE PIN CLAMPS NSN 6515-01-605-2257, (1)CONNECTING ROD 11MM X 400MM NSN 6515-01-600-3377, (1)CONNECTING ROD 8MM X 250MM NSN 6515-01-600-3375, (4)SELF-DRILLING PINS 5MM X 180MM NSN 6515-01-513-1261, (4)SELF-DRILLING PINS 3/5MM X 120MM NSN 6515-01-600-4135, (1)PIN DRIVER/WRENCH ASSEMBLY PART NO. 5194-6-000, (1) NO. 10 SCALPEL, (1) MOSQUITO HEMOSTAT CLAMP; DIMENSIONS: 17 IN L X 5 IN W X 2 IN D; WEIGHT: 2.0 LB LBS; Part Name Assigned by Controlling Agency: EXTERNAL FIXATOR, FIELD PACK, ROLE OF CARE 2; HOFFMANN 3.. 2 total characteristics are documented in the Federal Logistics Information System.

Is NSN 6515-01-609-7248 still in active supply?

NSN 6515-01-609-7248 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com