The Suture,absorbable,surgical, cataloged under National Stock Number 6515-01-603-7151, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Defense Medical Standardization Board. Government technical data includes 11 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 6 commercial cross-references from 6 manufacturers, enabling identification through both NSN and commercial part number lookups. 9 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: BX.
| Parameter | Value |
|---|---|
| NSN | 6515-01-603-7151 |
| Primary Part Number | 6515NCM127322 |
| Item Name | Suture,absorbable,surgical |
| FSC / FSG | 6515 / 65 — No Item Name Available |
| Manufacturer | Defense Medical Standardization Board |
| Status | ACTIVE |
| Armed Suture Needle Style | 1/2 CIRCLE |
| Armed Suture Needle Point Style | ROUND TAPER |
| Material | STEEL CORROSION RESISTING NEEDLE |
| Strand Fiber Arrangement | MONOFILAMENT |
| End Type | SINGLE ARMED |
| Sterility | STERILE |
| Needle Nominal Length | 0.875 INCHES IN |
| Size Designator | 000 |
| Length | 2.250 FEET NOMINAL FT |
| Diameter | 0.280 MILLIMETERS NOMINAL MM |
| Material | CHROMIC GUT SUTURE |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Unit of Issue | BX |
| Part Number | Manufacturer |
|---|---|
| 6515NCM127322 | Defense Medical Standardization Board (USA) |
| 1377651 | Clifford Hallam Healthcare Pty Ltd (AUS) |
| G182H | Ethicon, Inc (USA) |
| A066031/0 | B Braun Australia Pty Ltd (AUS) |
| G-182H | Johnson & Johnson Medical Pty Ltd (AUS) |
| 32116 | Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA) |
NSN 6515-01-603-7151 is a Suture,absorbable,surgical, manufactured by Defense Medical Standardization Board, classified under FSC 6515 (No Item Name Available). Status: active.
NSN 6515-01-603-7151 has 6 cross-referenced part numbers: 6515NCM127322 (Defense Medical Standardization Board), 1377651 (Clifford Hallam Healthcare Pty Ltd), G182H (Ethicon, Inc), A066031/0 (B Braun Australia Pty Ltd), G-182H (Johnson & Johnson Medical Pty Ltd) and 1 more.
There are 9 known substitutes for 6515-01-603-7151: 6515-00-225-9585, 5330-00-341-9866, 5330-00-414-1859 and 6 more. Verify interchangeability with system specifications before substitution.
Key specifications for 6515NCM127322: Armed Suture Needle Style: 1/2 CIRCLE; Armed Suture Needle Point Style: ROUND TAPER; Part Name Assigned by Controlling Agency: SUTURE ABS GUT SZ 0 2.25FT L B3 1/2 CIR C7 RD TAPER 36S FT; Special Features: THREE PACKETS OF 12 FOR A TOTAL OF 36; REPLACEMENT NSN FOR 6515-00-225-9585. 13 total characteristics are documented in the Federal Logistics Information System.