PartsTable TECHNICAL DATA SHEET
NSN 6515-01-600-4681Government record, cited

Catheterization Kit, Intravenous6515-01-600-4681

NSN 6515-01-600-4681 · NIIN 016004681 · Part number CS-15553-E
Teleflex Medical · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE B6451
Government record, cited
NSN 6515-01-600-4681 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-600-4681. Manufacturer of record part number: CS-15553-E.
Also searched as  6515-01-600-4681 · 6515016004681 · NIIN 016004681 · 01-600-4681 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE B6451 · CS-15553-E
Nearby stock numbers  ·
Features
  • Catheterization Kit,intravenous — FSC 6515
  • End Item Source: 60791
  • Component Document Origin: INDUSTRIAL
  • End Item Name: PEDRIATIC MULTI-LUMEN CENTRAL VENOUS CATHERIZATION SET
  • 2 manufacturer part numbers on file
  • Manufacturer of record: Teleflex Medical
Identification
  • NSN: 6515-01-600-4681
  • NIIN: 016004681
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: CS-15553-E
  • Manufacturer: Teleflex Medical
General Description

The Catheterization Kit,intravenous, cataloged under National Stock Number 6515-01-600-4681, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Teleflex Medical. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-600-4681
Primary Part NumberCS-15553-E
Item NameCatheterization Kit,intravenous
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerTeleflex Medical
StatusACTIVE
End Item Source60791
Component Document OriginINDUSTRIAL
End Item NamePEDRIATIC MULTI-LUMEN CENTRAL VENOUS CATHERIZATION SET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
CS-15553-E Teleflex Medical (BEL)
CS-15553-E Teleflex Medical (FRA)
Reference documents
ReferenceMeaning
CS-15553-E 3/9 Design control — primary reference
Arrow International, Inc. Dba Teleflex
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-600-4681?

NSN 6515-01-600-4681 is a Catheterization Kit,intravenous, manufactured by Teleflex Medical, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-600-4681?

NSN 6515-01-600-4681 has 2 manufacturer part numbers on file: CS-15553-E (Teleflex Medical), CS-15553-E (Teleflex Medical).

What are the specifications of CS-15553-E?

Key specifications for CS-15553-E: End Item Source: 60791; Component Document Origin: INDUSTRIAL; End Item Name: PEDRIATIC MULTI-LUMEN CENTRAL VENOUS CATHERIZATION SET; Special Features: C/O 1 SPRING WIRE GUIDE; 1 FASTNER; CATHER CLAM, ONE INTRODUCER NEEDLE, 1 CATHETER 22 GA. X 1-3/4 (4.45 CM) RADIOPAQUE OVER 25 GA. RW INTRODUCER NEEDLE WITH 5CC LUER-SLIP SYRINGE; 2 TISSUE DILATOR; 1 CLAMP CATHETER CM. 3 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-600-4681 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com