PartsTable TECHNICAL DATA SHEET
NSN 6515-01-599-8568Government record, cited

Transducer, Blood Pressure, Invasi6515-01-599-8568

NSN 6515-01-599-8568 · NIIN 015998568 · Part number CPJ840J6
Philips North America Llc Dba Philips Healthcare · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0ZBJ4
Government record, cited
NSN 6515-01-599-8568 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-599-8568. Manufacturer of record part number: CPJ840J6.
Also searched as  6515-01-599-8568 · 6515015998568 · NIIN 015998568 · 01-599-8568 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 0ZBJ4 · CPJ840J6 · 25273 · 6515NCM116428
Nearby stock numbers  ·
Features
  • Transducer,blood Pressure,invasi — FSC 6515
  • Storage Temp Range: -20.0 TO 70.0 CELSIUS DEGC
  • 1 manufacturer part number on file
  • Manufacturer of record: Philips North America Llc Dba Philips Healthcare
Identification
  • NSN: 6515-01-599-8568
  • NIIN: 015998568
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: CPJ840J6
  • Manufacturer: Philips North America Llc Dba Philips Healthcare
General Description

The Transducer,blood Pressure,invasi, cataloged under National Stock Number 6515-01-599-8568, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Philips North America Llc Dba Philips Healthcare. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-599-8568
Primary Part NumberCPJ840J6
Item NameTransducer,blood Pressure,invasi
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerPhilips North America Llc Dba Philips Healthcare
StatusACTIVE
Storage Temp Range-20.0 TO 70.0 CELSIUS DEGC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
CPJ840J6 PRIMARY Philips North America Llc Dba Philips Healthcare (USA)
Reference documents
ReferenceMeaning
25273 5/1 Secondary reference
U.S. Government activity
6515NCM116428 5/1 Secondary reference
Defense Medical Standardization Board

Frequently Asked Questions

What is NSN 6515-01-599-8568?

NSN 6515-01-599-8568 is a Transducer,blood Pressure,invasi, manufactured by Philips North America Llc Dba Philips Healthcare, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-599-8568?

NSN 6515-01-599-8568 has 1 manufacturer part number on file: CPJ840J6 (Philips North America Llc Dba Philips Healthcare).

What are the specifications of CPJ840J6?

Key specifications for CPJ840J6: Storage Temp Range: -20.0 TO 70.0 CELSIUS DEGC; Special Features: TRANSDUCER, BLOOD PRESSURE, INVASIVE; PIEZORESISTIVE; REUSABLE; INCLUDES: 3 METER (118 IN) LONG CABLE, DISPOSABLE SILICONE DOME, TRANSDUCER, TRANSDUCER HOLDER; FOR CONTINUOUS ARTERIAL OR VENOUS BLOOD PRESSURE MEASUREMENT; PRESSURE RANGE: -20 TO +300 MM HG; MAX OVERPRESSURE: 1000 MM HG; SENSITIVITY: 50 MICRO V/V/CM HG; RESONANCE FREQ: 300 HZ TYPICAL WITH TRANSDUCER DOME; MAX ELECTRICAL EXITATION: 15 V DC OR AC; INPUT RESISTANCE: 700 OHM DC AND 350 OHM AC; OUTPUT RESISTANCE: 1000 OHMS; OPERATING TEMPERATURE: 10 TO 50 DEG C; NON-LINEARITY AND HYSTERESIS: MAX 0.5 PCT OF FULL SCALE; ZERO BALANCE: MAX +/- 30 MM HG; THERMAL SENSITIVITY SHIFT: 0.15 PCT/DEG C; THERMAL ZERO SHIFT: MAX 0.15 MM HG/DEG C V; Part Name Assigned by Controlling Agency: TRANSDUCER AND CABLE BLOOD PRESSURE CPJ840J6; End Item Identification: 6515-01-586-5646 MONITOR, PATIENT VITAL SIGNS. 1 specification is documented in the U.S. Government catalog.

Is NSN 6515-01-599-8568 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com