The Transducer,blood Pressure,invasi, cataloged under National Stock Number 6515-01-599-8568, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Philips North America Llc Dba Philips Healthcare. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-599-8568 |
| Primary Part Number | CPJ840J6 |
| Item Name | Transducer,blood Pressure,invasi |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Philips North America Llc Dba Philips Healthcare |
| Status | ACTIVE |
| Storage Temp Range | -20.0 TO 70.0 CELSIUS DEGC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| CPJ840J6 PRIMARY | Philips North America Llc Dba Philips Healthcare (USA) |
| Reference | Meaning |
|---|---|
| 25273 | 5/1 Secondary reference U.S. Government activity |
| 6515NCM116428 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6515-01-599-8568 is a Transducer,blood Pressure,invasi, manufactured by Philips North America Llc Dba Philips Healthcare, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-599-8568 has 1 manufacturer part number on file: CPJ840J6 (Philips North America Llc Dba Philips Healthcare).
Key specifications for CPJ840J6: Storage Temp Range: -20.0 TO 70.0 CELSIUS DEGC; Special Features: TRANSDUCER, BLOOD PRESSURE, INVASIVE; PIEZORESISTIVE; REUSABLE; INCLUDES: 3 METER (118 IN) LONG CABLE, DISPOSABLE SILICONE DOME, TRANSDUCER, TRANSDUCER HOLDER; FOR CONTINUOUS ARTERIAL OR VENOUS BLOOD PRESSURE MEASUREMENT; PRESSURE RANGE: -20 TO +300 MM HG; MAX OVERPRESSURE: 1000 MM HG; SENSITIVITY: 50 MICRO V/V/CM HG; RESONANCE FREQ: 300 HZ TYPICAL WITH TRANSDUCER DOME; MAX ELECTRICAL EXITATION: 15 V DC OR AC; INPUT RESISTANCE: 700 OHM DC AND 350 OHM AC; OUTPUT RESISTANCE: 1000 OHMS; OPERATING TEMPERATURE: 10 TO 50 DEG C; NON-LINEARITY AND HYSTERESIS: MAX 0.5 PCT OF FULL SCALE; ZERO BALANCE: MAX +/- 30 MM HG; THERMAL SENSITIVITY SHIFT: 0.15 PCT/DEG C; THERMAL ZERO SHIFT: MAX 0.15 MM HG/DEG C V; Part Name Assigned by Controlling Agency: TRANSDUCER AND CABLE BLOOD PRESSURE CPJ840J6; End Item Identification: 6515-01-586-5646 MONITOR, PATIENT VITAL SIGNS. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.