The Ventilator,volume,portable, cataloged under National Stock Number 6515-01-598-7255, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Pulmonetic Systems. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-598-7255 |
| Primary Part Number | 18888-01 |
| Item Name | Ventilator,volume,portable |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Pulmonetic Systems |
| Status | ACTIVE |
| Frequency in Hertz | 50.0 OR 60.0 |
| Current Type | AC/DC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 18888-01 PRIMARY | Pulmonetic Systems (USA) |
| Reference | Meaning |
|---|---|
| 25344 | 5/1 Secondary reference U.S. Government activity |
| 6515NCM116593 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6515-01-598-7255 is a Ventilator,volume,portable, manufactured by Pulmonetic Systems, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-598-7255 has 1 manufacturer part number on file: 18888-01 (Pulmonetic Systems).
Key specifications for 18888-01: Frequency in Hertz: 50.0 OR 60.0; Current Type: AC/DC; Special Features: PRESETS TO ALLOW RAPID PATIENT SET-UP; NPPV6, CPAP4, SIMV5, CONTROL, ASSIST/CONTROL, AND APNEA BACKUP VENTILATION MODES; VARIABLE ALARM SETTINGS; OXYGEN BLENDING, VOLUME CONTROL, PRESSURE CONTROL, AND PRESSURE SUPPORT VENTILATION; LOCKABLE FRONT PANEL CONTROLS; HIGH PERFORMANCE TURBINE TECHNOLOGY ALLOWS VENTILATOR TO OPERATE WITHOUT AN EXTERNAL COMPRESSED GAS SOURCE; OPERATES FROM A VARIETY OF POWER SOURCES, SUCH AS AC POWER, INTERNAL BATTERY, AND EXTERNAL DC; AC ADAPTER INPUT: 100 TO 250 VAC, 50 TO 60 HZ, OUTPUT: 13 VDC; INPUT VOLTAGE: 11 TO 15 VDC; INTERNAL BATTERY: 12 V SEALED LEAD ACID, 4.5 AH; ALSO INCLUDES: DUST COVER, PROTECTIVE BOOTS, AC POWER CONVERTER, OPERATOR MANUAL, AND QUICK REFERENCE GUIDE VDC; Part Name Assigned by Controlling Agency: LTV1200. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.