PartsTable TECHNICAL DATA SHEET
NSN 6515-01-592-4074Government record, cited

Retrograde Intubation Set6515-01-592-4074

NSN 6515-01-592-4074 · NIIN 015924074 · Part number G57614
Cook Medical Llc · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 393H0
Government record, cited
NSN 6515-01-592-4074 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-592-4074. Manufacturer of record part number: G57614.
Also searched as  6515-01-592-4074 · 6515015924074 · NIIN 015924074 · 01-592-4074 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 393H0 · G57614 · 6515NCM115948 · 18995 · 1646G10554 · G10554
Nearby stock numbers  ·
Features
  • Retrograde Intubation Set — FSC 6515
  • 2 manufacturer part numbers on file
  • Manufacturer of record: Cook Medical Llc
Identification
  • NSN: 6515-01-592-4074
  • NIIN: 015924074
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: G57614
  • Manufacturer: Cook Medical Llc
General Description

The Retrograde Intubation Set, cataloged under National Stock Number 6515-01-592-4074, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cook Medical Llc. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-592-4074
Primary Part NumberG57614
Item NameRetrograde Intubation Set
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerCook Medical Llc
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5305-01-597-569312759-01247 POSSIBLE MATCH
SCREW,CAP,HEXAGON HEAD
Possible match (shared part number)Fastenal Company Dba Fastenal Co
Cross-Reference Index
Part NumberManufacturer
G57614 PRIMARY Cook Medical Llc (USA)
1646G10554 Owens & Minor Distribution Inc (USA)
Reference documents
ReferenceMeaning
6515NCM115948 5/1 Secondary reference
Defense Medical Standardization Board
18995 5/1 Secondary reference
U.S. Government activity
G10554 3/1 Design control — primary reference
Cook Medical Llc
Related Parts
5305-01-597-5693POSSIBLE MATCH
SCREW,CAP,HEXAGON HEAD
12759-01247

Frequently Asked Questions

What is NSN 6515-01-592-4074?

NSN 6515-01-592-4074 is a Retrograde Intubation Set, manufactured by Cook Medical Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-592-4074?

NSN 6515-01-592-4074 has 2 manufacturer part numbers on file: G57614 (Cook Medical Llc), 1646G10554 (Owens & Minor Distribution Inc).

What NSN replaces 6515-01-592-4074?

1 possible match (shared part number, not a government interchangeability claim): 5305-01-597-5693. Verify interchangeability with system specifications before substitution.

What are the specifications of G57614?

Key specifications for G57614: Special Features: STERILE; DISPOSABLE; CATHETER SIZE: 14 FR; CATHETER LENGTH: 70 CM; WIRE GUIDE DIAMETER: 0.038 IN; WIRE GUIDE LENGTH: 110 CM; WIRE GUIDE TIP: STRAIGHT AND 3 MM J; USE WITH ENDOTRACHEAL TUBE WITH INNER DIAMETER 5.0 MM OR LARGER; SET INCLUDES: (1) RETROGRADE INTUBATION CATHETER, (1) STRAIGHT AND CURVED SAFE-T-J DOUBLE FLEXIBLE TIPPED STAINLESS STEEL WIRE GUIDE, (1) TFE CATHETER NEEDLE, (1) PERCUTANEOUS ENTRY NEEDLE, (1) SYRINGE, (1) SHARPS NEEDLE HOLDER, AND (2) RAPI-FIT ADAPTERS: ONE FOR JET VENTILATION CONNECTION AND ONE FOR STANDARD 15 MM CONNECTION MM; Part Name Assigned by Controlling Agency: SET CATHETER GUIDING RETROGRADE INTUBATION 14FR 70CM L 0.038 GUIDEWIRE CM. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-592-4074 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com