PartsTable TECHNICAL DATA SHEET
NSN 6515-01-583-6336Government record, cited

Catheter, Cardiovascular6515-01-583-6336

NSN 6515-01-583-6336 · NIIN 015836336 · Part number 7481-23
Merit Medical Systems Inc · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0VS26
Government record, cited
NSN 6515-01-583-6336 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-583-6336. Manufacturer of record part number: 7481-23.
Also searched as  6515-01-583-6336 · 6515015836336 · NIIN 015836336 · 01-583-6336 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 0VS26 · 7481-23
Nearby stock numbers  ·
Features
  • Catheter,cardiovascular — FSC 6515
  • Supplementary Features: USED FOR CORONARY ANGIOGRAPHY;CORONARY ATERIOGRAPHY-NARROWING OF ARTERIES
  • Style Designator: AORTOGRAM
  • Catheter Nominal Length: 100.0 CENTIMETERS CM
  • Design Designation: AORTOGRAM
  • Tip Type: CURVED
  • Inside Diameter: 0.051 INCHES NOMINAL IN
  • Nominal Diameter: 6.000 FRENCH
Identification
  • NSN: 6515-01-583-6336
  • NIIN: 015836336
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 7481-23
  • Manufacturer: Merit Medical Systems Inc
General Description

The Catheter,cardiovascular, cataloged under National Stock Number 6515-01-583-6336, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Merit Medical Systems Inc. Government technical data includes 9 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-583-6336
Primary Part Number7481-23
Item NameCatheter,cardiovascular
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerMerit Medical Systems Inc
StatusACTIVE
Supplementary FeaturesUSED FOR CORONARY ANGIOGRAPHY;CORONARY ATERIOGRAPHY-NARROWING OF ARTERIES
Style DesignatorAORTOGRAM
Catheter Nominal Length100.0 CENTIMETERS CM
Design DesignationAORTOGRAM
Tip TypeCURVED
Inside Diameter0.051 INCHES NOMINAL IN
Nominal Diameter6.000 FRENCH
MaterialPLASTIC POLYURETHANE CATHETER
Shaft Eye Quantity4
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
7481-23 PRIMARY Merit Medical Systems Inc (USA)
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-583-6336?

NSN 6515-01-583-6336 is a Catheter,cardiovascular, manufactured by Merit Medical Systems Inc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-583-6336?

NSN 6515-01-583-6336 has 1 manufacturer part number on file: 7481-23 (Merit Medical Systems Inc).

What are the specifications of 7481-23?

Key specifications for 7481-23: Supplementary Features: USED FOR CORONARY ANGIOGRAPHY;CORONARY ATERIOGRAPHY-NARROWING OF ARTERIES; Style Designator: AORTOGRAM; Catheter Nominal Length: 100.0 CENTIMETERS CM; Design Designation: AORTOGRAM. 9 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-583-6336 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com