The Dose Drawing System, cataloged under National Stock Number 6515-01-581-8184, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Biodex Medical Systems, Inc. Dba Biodex Medical Systems Inc Div Medical Division. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6515-01-581-8184 |
| Primary Part Number | 042-466 |
| Item Name | Dose Drawing System |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Biodex Medical Systems, Inc. Dba Biodex Medical Systems Inc Div Medical Division |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 042-466 PRIMARY | Biodex Medical Systems, Inc. Dba Biodex Medical Systems Inc Div Medical Division (USA) |
NSN 6515-01-581-8184 is a Dose Drawing System, manufactured by Biodex Medical Systems, Inc. Dba Biodex Medical Systems Inc Div Medical Division, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-581-8184 has 1 manufacturer part number on file: 042-466 (Biodex Medical Systems, Inc. Dba Biodex Medical Systems Inc Div Medical Division).
1 possible match (shared part number, not a government interchangeability claim): 3120-01-621-4877. Verify interchangeability with system specifications before substitution.
Key specifications for 042-466: Special Features: DRAWS FDG-18 DOSES FROM A VIAL; CONSISTS OF A SPECIALLY DESIGNED SYRINGE SHIELD, VIAL AND STAND; STAND ALLOWS THE VIAL SHIELD TO ROTATE AND HAS A FIXED STOP AT 45 DEG DOWNWARD ANGLE; VIAL SHIELD IS CONSTRUCTED OF 1 INCH LEAD ENCASSED IN STEEL; THREADED SHIELD TOP; TUNGSTEN SYRINGE SHIELD IS MOUNTED ON A STAINLESS STEEL ROTATING PLATFORM THAT SLIDES THE SYRINGE INTO THE VIAL AND LOCKES INTO POSITION; DOSE IS DRAWN WITH FORCEPS IN. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.