PartsTable TECHNICAL DATA SHEET
NSN 6515-01-573-0608Government record, cited

Guide Wire, Cardiovascular Cathet6515-01-573-0608

NSN 6515-01-573-0608 · NIIN 015730608 · Part number 103-0602-300
Ev3 Inc. Dba Covidien · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 03NN1
Government record, cited
NSN 6515-01-573-0608 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-573-0608. Manufacturer of record part number: 103-0602-300.
Also searched as  6515-01-573-0608 · 6515015730608 · NIIN 015730608 · 01-573-0608 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 03NN1 · 103-0602-300
Nearby stock numbers  ·
Features
  • Guide Wire,cardiovascular Cathet — FSC 6515
  • Overall Diameter: 0.014 INCHES NOMINAL IN
  • Material: STEEL CORROSION RESISTING OVERALL
  • 1 manufacturer part number on file
  • Manufacturer of record: Ev3 Inc. Dba Covidien
Identification
  • NSN: 6515-01-573-0608
  • NIIN: 015730608
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 103-0602-300
  • Manufacturer: Ev3 Inc. Dba Covidien
General Description

The Guide Wire,cardiovascular Cathet, cataloged under National Stock Number 6515-01-573-0608, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Ev3 Inc. Dba Covidien. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-573-0608
Primary Part Number103-0602-300
Item NameGuide Wire,cardiovascular Cathet
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerEv3 Inc. Dba Covidien
StatusACTIVE
Overall Diameter0.014 INCHES NOMINAL IN
MaterialSTEEL CORROSION RESISTING OVERALL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
103-0602-300 PRIMARY Ev3 Inc. Dba Covidien (USA)
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-573-0608?

NSN 6515-01-573-0608 is a Guide Wire,cardiovascular Cathet, manufactured by Ev3 Inc. Dba Covidien, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-573-0608?

NSN 6515-01-573-0608 has 1 manufacturer part number on file: 103-0602-300 (Ev3 Inc. Dba Covidien).

What are the specifications of 103-0602-300?

Key specifications for 103-0602-300: Overall Diameter: 0.014 INCHES NOMINAL IN; Overall Length: 300.0 CENTIMETERS NOMINAL CM; Special Features: WITH A RADIOPAQUE PLATINUM DISTAL COIL; HYDROPHILICALLY COATED ON THE DISTAL PORTION; PROXIMAL PORTION COATED WITH POLYTETRAFLUOROETHYLENE; INCLUDED WITH THE STERILE POUCH IS A TORQUE DEVICE TO ASSIST GUIDEWIRE MANIPULATION AND GUIDEWIRE INTRODUCER; FOR GENERAL INTRAVASCULAR USE TO AID IN THE SELECTIVE PLACEMENT OF CATHETERS IN THE PERIPHERAL, VISCERAL AND CEREBRAL VASCULATURE DURING DIAGNOSTIC AND/OR THERAPEUTIC PROCEDURES; Part Name Assigned by Controlling Agency: X-CELERATOR HYDROPHILIC EXCHANGE GUIDEWIRE. 2 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-573-0608 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com