The Clip,aneurysm, cataloged under National Stock Number 6515-01-568-1275, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Trillamed Llc. Government technical data includes 3 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-568-1275 |
| Primary Part Number | TM-FE820K |
| Item Name | Clip,aneurysm |
| FSC / FSG | 6515 / 65 — No Item Name Available |
| Manufacturer | Trillamed Llc |
| Status | ACTIVE |
| Features Provided | STERILE |
| Material | COBALT ALLOY OVERALL |
| Design Designation | YASARGIL |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 6515NCM082782 | Defense Medical Standardization Board (USA) |
| 8976 | Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA) |
| TM-FE820K PRIMARY | Trillamed Llc (USA) |
| FE820K PRIMARY | Aesculap, Inc (USA) |
| PHYNOX | Aesculap, Inc (USA) |
NSN 6515-01-568-1275 is a Clip,aneurysm, manufactured by Trillamed Llc, classified under FSC 6515 (No Item Name Available). Status: active.
NSN 6515-01-568-1275 has 5 cross-referenced part numbers: 6515NCM082782 (Defense Medical Standardization Board), 8976 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia), TM-FE820K (Trillamed Llc), FE820K (Aesculap, Inc), PHYNOX (Aesculap, Inc).
There are 12 known substitutes for 6515-01-568-1275: 2915-00-024-5789, 5360-00-076-9596, 4320-00-394-2757 and 9 more. Verify interchangeability with system specifications before substitution.
Key specifications for TM-FE820K: Part Name Assigned by Controlling Agency: CLIP ANEURYSM YASARGIL PHYNOX 7MM BLADE 90 DEG ANGLE STER MM; Features Provided: STERILE; Special Features: PERMANENT; 7.0 MM BLADE, 90 DEG ANGLED; NON-MAGNETIC; MRI SAFE UP TO 3 TESLA; PHYNOX (CO-CR-NI) ALLOY; 4.5 MM MAX OPENING; 200 GM (1.96 N) CLOSING FORCE; CAN BE RESTERILIZED PROVIDED IT HAS NOT MADE CONTACT WITH A PATIENT PRIOR TO RESTERILIZATION MM; Material: COBALT ALLOY OVERALL. 5 total characteristics are documented in the Federal Logistics Information System.