The Implant,arterial, cataloged under National Stock Number 6515-01-567-3716, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Gf Labor Comercio E Representacoes Ltda. Government technical data includes 9 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6515-01-567-3716 |
| Primary Part Number | STENT REVESTIDO NR 8 |
| Item Name | Implant,arterial |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Gf Labor Comercio E Representacoes Ltda |
| Status | ACTIVE |
| Design Form | ONE-PIECE |
| Supplementary Features | HAS 3 RADIOPAQUE MARKERS;2 END MARKERS,1 AT EACH END AND 1 MARKER LOCATED 3CM BELOW THE PROXIMAL END CM |
| Shape | STRAIGHT |
| Design Designation | VASCULAR |
| Features Provided | HOLLOW |
| Inside Diameter | 10.0 MILLIMETERS NOMINAL MM |
| Construction | WOVEN FABRIC |
| Material | PLASTIC POLYTETRAFLUOROETHYLENE |
| Usage Design | USE AFTER DEPLOYMENT OF GORE EXCLUDER BIFURCATED ENOPROSTHESIS AS ADDITIONAL LENGTH AND/OR SEALING FOR ANEURYSMAL EXCLUSION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| STENT REVESTIDO NR 8 | Gf Labor Comercio E Representacoes Ltda (BRA) |
| Reference | Meaning |
|---|---|
| PXL161007 | 3/9 Design control — primary reference Wl Gore & Associates Inc |
NSN 6515-01-567-3716 is a Implant,arterial, manufactured by Gf Labor Comercio E Representacoes Ltda, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-567-3716 has 1 manufacturer part number on file: STENT REVESTIDO NR 8 (Gf Labor Comercio E Representacoes Ltda).
Key specifications for STENT REVESTIDO NR 8: Design Form: ONE-PIECE; Supplementary Features: HAS 3 RADIOPAQUE MARKERS;2 END MARKERS,1 AT EACH END AND 1 MARKER LOCATED 3CM BELOW THE PROXIMAL END CM; Shape: STRAIGHT; Overall Length: 70.0 MILLIMETERS NOMINAL MM. 9 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.