The Balloon Catheter,vascular-Nonvas, cataloged under National Stock Number 6515-01-564-1409, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cook Medical Llc. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-564-1409 |
| Primary Part Number | G36042 |
| Item Name | Balloon Catheter,vascular-Nonvas |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Cook Medical Llc |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| G36042 PRIMARY | Cook Medical Llc (USA) |
| Reference | Meaning |
|---|---|
| CODA | 5/1 Secondary reference Cook Medical Llc |
| 8237 | 5/1 Secondary reference U.S. Government activity |
| 6510NCM082582 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6515-01-564-1409 is a Balloon Catheter,vascular-Nonvas, manufactured by Cook Medical Llc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-564-1409 has 1 manufacturer part number on file: G36042 (Cook Medical Llc).
2 possible matches (shared part number, not a government interchangeability claim): 6625-01-627-9728, 5977-01-721-4235. Verify interchangeability with system specifications before substitution.
Key specifications for G36042: Special Features: FOR TEMPORARY OCCLUSION POST TRANSLUMINAL ANGIOPLASTY; CATHETER 10 FR SIZE, 100 CM LENGTH; RECOMMENDED INTRODUCER SIZE: 14 FR; BALLOON MAX. INFLATED DIA: 32 MM; ACCEPTS 0.035 IN DIA GUIDE WIRE; MAX. BALLOON INFLATION VOL: 34 CC; RADIOPAQUE MARKERS; STERILE MM; Part Name Assigned by Controlling Agency: CATHETER BALLOON TEMP PTA OCCLUSION 10FR 32MM 100CM L MM. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.