The Oximeter,pulse, cataloged under National Stock Number 6515-01-559-5608, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Medilon Ltd. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6515-01-559-5608 |
| Primary Part Number | NELLCOR OXIMAX N-560 |
| Item Name | Oximeter,pulse |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Medilon Ltd |
| Status | ACTIVE |
| Mounting Stand | NOT PROVIDED |
| Carrying Case | NOT PROVIDED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| NELLCOR OXIMAX N-560 | Medilon Ltd (BGR) |
| NELLCOR OXIMAX N-560 | Tyco Healthcare Group Ag (CHE) |
| Reference | Meaning |
|---|---|
| OXIMAX N-560 | 5/9 Secondary reference Nellcor Puritan Bennett Llc Dba Covidien Div Covidien |
| N-560 | 3/9 Design control — primary reference Nellcor Puritan Bennett Llc Dba Covidien Div Covidien |
NSN 6515-01-559-5608 is a Oximeter,pulse, manufactured by Medilon Ltd, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-559-5608 has 2 manufacturer part numbers on file: NELLCOR OXIMAX N-560 (Medilon Ltd), NELLCOR OXIMAX N-560 (Tyco Healthcare Group Ag).
Key specifications for NELLCOR OXIMAX N-560: Mounting Stand: NOT PROVIDED; Special Features: COMPACT SIZE, SIMPLE, INTUTIVE OPERATION, 24-HOUR DOWNLOADABLE TREND MEMORY, EQUIPPED WITH SATSECONDS ALARM MANAGEMENT, ADVANCED SIGNAL PROCESSING ENHANCES PERFORMANCE DURING LOW PERFUSION AND SIGNAL INTERFERENCE, INCLUDING PATIENT MOTION; Carrying Case: NOT PROVIDED. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.