PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

6515NCM071948Endoscopic Instrument,fiber Opti

Defense Medical Standardization Board · NSN 6515-01-556-0098 · FSC 6515 · No Item Name Available
Verified by PartsTable
NSN 6515-01-556-0098 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-556-0098. Primary manufacturer part number: 6515NCM071948.
Features
  • Endoscopic Instrument,fiber Opti — FSC 6515
  • Universal Medical Device Nomenclature System Code: 20476
  • 4 verified cross-references
  • Primary manufacturer: Defense Medical Standardization Board
Applications
  • Industrial maintenance and repair
  • Government and military logistics
  • Equipment overhaul and refurbishment
General Description

The Endoscopic Instrument,fiber Opti, cataloged under National Stock Number 6515-01-556-0098, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Defense Medical Standardization Board. Government technical data includes 1 verified specification, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-556-0098
Primary Part Number6515NCM071948
Item NameEndoscopic Instrument,fiber Opti
FSC / FSG6515 / 65 — No Item Name Available
ManufacturerDefense Medical Standardization Board
StatusACTIVE
Universal Medical Device Nomenclature System Code20476
Lifecycle & Compliance
Acquisition StatusACTIVE
Successor6515-01-528-6157 (MB-146)
HAZMATNo
Unit of IssueEA
Verified Substitutes 12
Insert and Tool Assortment,screw
6515-01-528-6157MB-146 SUCCESSOR
Lubricant,surgical Instruments
Olympus America Inc
6515-01-528-6158MH-507 SUCCESSOR
Brush,cleaning,endoscope
Olympus America Inc
6515-01-555-3974MAJ891 SUCCESSOR
Plug,endoscope
Olympus America Inc
5961-00-076-6459 INTERCHANGEABLE
Semiconductor Device,photo
5930-00-175-458902-16-009 INTERCHANGEABLE
Switch,thermostatic
Hatco Corp
6625-00-190-48684934 INTERCHANGEABLE
Transducer Assembly
Precision Electronics, Inc
5330-00-298-6529RE49F212-6 INTERCHANGEABLE
Gasket
Naval Ship Systems Command
5945-00-883-9480 INTERCHANGEABLE
Relay,electromagnetic
2040-00-896-67874934 INTERCHANGEABLE
Galilean Eyepiece C
L3 Technologies, Inc. Div L3 Keo
Cross-Reference Index
Part NumberManufacturer
6515NCM071948 Defense Medical Standardization Board (USA)
OLYMPUS Olympus America Inc Div Diagnostic Systems Group (USA)
4934 Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA)
LF-TP Olympus America Inc Div Diagnostic Systems Group (USA)
Related Parts
SUCCESSOR 6515-01-528-6157 Lubricant,surgical Instruments · MB-146
5340-01-392-1019SUCCESSOR
INSERT AND TOOL ASSORTMENT,SCREW
6515-01-528-6158SUCCESSOR
BRUSH,CLEANING,ENDOSCOPE
MH-507
6515-01-555-3974SUCCESSOR
PLUG,ENDOSCOPE
MAJ891
5961-00-076-6459INTERCHANGEABLE
SEMICONDUCTOR DEVICE,PHOTO
5930-00-175-4589INTERCHANGEABLE
SWITCH,THERMOSTATIC
02-16-009
6625-00-190-4868INTERCHANGEABLE
TRANSDUCER ASSEMBLY
4934
5330-00-298-6529INTERCHANGEABLE
GASKET
RE49F212-6
5945-00-883-9480INTERCHANGEABLE
RELAY,ELECTROMAGNETIC
2040-00-896-6787INTERCHANGEABLE
GALILEAN EYEPIECE C
4934
4720-01-017-2643INTERCHANGEABLE
HOSE,NONMETALLIC
4934
5915-01-029-3739INTERCHANGEABLE
FILTER,LOW PASS

Frequently Asked Questions

What is NSN 6515-01-556-0098?

NSN 6515-01-556-0098 is a Endoscopic Instrument,fiber Opti, manufactured by Defense Medical Standardization Board, classified under FSC 6515 (No Item Name Available). Status: active.

What are the part numbers for NSN 6515-01-556-0098?

NSN 6515-01-556-0098 has 4 cross-referenced part numbers: 6515NCM071948 (Defense Medical Standardization Board), OLYMPUS (Olympus America Inc Div Diagnostic Systems Group), 4934 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia), LF-TP (Olympus America Inc Div Diagnostic Systems Group).

What NSN replaces 6515-01-556-0098?

There are 12 known substitutes for 6515-01-556-0098: 5340-01-392-1019, 6515-01-528-6157, 6515-01-528-6158 and 9 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 6515NCM071948?

Key specifications for 6515NCM071948: Special Features: FIBEROPTIC BATTERY POWERED ENDOSCOPE; LARGE SUCTION CHANNEL AT CENTER, INCREASING SPUTA SUCTIONING CAPABILITY; 2.6MM DIA. CHANNEL INCORPORATED INTO AN INSERTION TUBE W/ OUTER DIA. OF 5.2 MM; COMPATIBLE W/MOST SINGLE LUMEN TRACHEAL TUBES FOR ADULTS; CAN BE USED IN EMERGENCY SITUATIONS,BEDSIDE, OPER. RM,, OR ICU; INTEGRATED MINIATURE LIGHT SOURCE MM; Part Name Assigned by Controlling Agency: FIBERSCOPE TRACHEAL INTUBATION BATTERY POWERED ENDOSCOPE; Universal Medical Device Nomenclature System Code: 20476. 3 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com