The Sensor,pulse Monitoring,oximeter, cataloged under National Stock Number 6515-01-554-9414, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Medtronic Usa Inc. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: PG.
| Parameter | Value |
|---|---|
| NSN | 6515-01-554-9414 |
| Primary Part Number | MAX-N |
| Item Name | Sensor,pulse Monitoring,oximeter |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Medtronic Usa Inc |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | PG |
| Part Number | Manufacturer |
|---|---|
| MAX-N PRIMARY | Medtronic Usa Inc (USA) |
| MAX-N | Vanguard Medical Concepts Inc (USA) |
| Reference | Meaning |
|---|---|
| OXIMAX | 5/9 Secondary reference Nellcor Puritan Bennett Llc Dba Covidien Div Covidien |
| 4205 | 5/1 Secondary reference U.S. Government activity |
| 6515NCM071624 | 5/1 Secondary reference Defense Medical Standardization Board |
| MAX-N | 5/9 Secondary reference Nellcor Puritan Bennett Llc Dba Covidien Div Covidien |
NSN 6515-01-554-9414 is a Sensor,pulse Monitoring,oximeter, manufactured by Medtronic Usa Inc, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-554-9414 has 2 manufacturer part numbers on file: MAX-N (Medtronic Usa Inc), MAX-N (Vanguard Medical Concepts Inc).
Key specifications for MAX-N: Special Features: DIGITAL MEMORY CHIP, STORES ALL THE CALIBRATION AND OPERATING CHARACTERISTICS FOR THAT TYPE OF SENSOR; ADHESIVE SENSOR FOR NEONATAL/ADULT (3KG OR 40KG); COMPATIBLE WITH ALL PULSE OXIMETERS AND MONITORING SYSTEMS CONTAINING NELLCOR TECHNOLOGY; PKG/24 KG; Part Name Assigned by Controlling Agency: SENSOR PULSE OXIMETER ADHESIVE OXIMAX NEONATAL/ADULT 24S. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.