The Pump,intravenous Infusion, cataloged under National Stock Number 6515-01-550-5669, is classified within Federal Supply Class 6515 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Carefusion Solutions, Llc Div Mms. Government technical data includes 1 verified specification, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 8 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-550-5669 |
| Primary Part Number | MED SYSTEM III |
| Item Name | Pump,intravenous Infusion |
| FSC / FSG | 6515 / 65 — No Item Name Available |
| Manufacturer | Carefusion Solutions, Llc Div Mms |
| Status | ACTIVE |
| Universal Medical Device Nomenclature System Code | 17634 |
| Acquisition Status | ACTIVE |
| Successor | 6515-01-445-7327 (2865B) |
| HAZMAT | No |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| MED SYSTEM III | Carefusion Solutions, Llc Div Mms (USA) |
| MSIIISYS-SS | Carefusion Solutions, Llc Div Mms (USA) |
| 6515NCM071294 | Defense Medical Standardization Board (USA) |
| 3353 | Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA) |
NSN 6515-01-550-5669 is a Pump,intravenous Infusion, manufactured by Carefusion Solutions, Llc Div Mms, classified under FSC 6515 (No Item Name Available). Status: active.
NSN 6515-01-550-5669 has 4 cross-referenced part numbers: MED SYSTEM III (Carefusion Solutions, Llc Div Mms), MSIIISYS-SS (Carefusion Solutions, Llc Div Mms), 6515NCM071294 (Defense Medical Standardization Board), 3353 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia).
There are 8 known substitutes for 6515-01-550-5669: 6515-01-445-7327, 5360-00-314-7167, 2910-00-504-1370 and 5 more. Verify interchangeability with system specifications before substitution.
Key specifications for MED SYSTEM III: Part Name Assigned by Controlling Agency: PUMP INTRAVENOUS INFUSION 3-CHANNEL MEDSYSTEM III VOLUMETRIC PTB W/ADMIN SETS; Universal Medical Device Nomenclature System Code: 17634; Special Features: PORTABLE; LINE POWERED OR BATTERY OPERATED;BATTERY CHARGER PACK RATED 115/230 VAC, 50/60 HZ WHILE PUMP IS OPERATING; BATTERY OPERATES 4 HRS AT A FLOW RATE OF 125 ML/HR ON A SINGLE CHARGE; CAPABLE OF PRE-SELECTING A VOLUME TO BE ADMINISTERED FROM 1 TO 999 MLS PER CHANNEL; RATE OF FLOW FROM 1 ML PER HR TO 200 HRS IN 1 ML INCREMENTS; AUDIBLE AND VISIBLE AIR IN LINE ALARM; VISIBLE LOW BATTERY ALARM OPERATES 1 HR TO REQUIRED RECHARGING BATTERY; OCCLUSION ALARM INDICATES OCCLUDED TUBING OR CLOGGED FILTER; AUDIBLE ALARM INDICATES COMPLETION OF INFUSION; TAMPER PROOF FEATURE TO LESSEN THE EFFECTS OF INTENTIONAL REMOVAL AND/OR ACCIDENTAL REMOVAL OF THE SET/CASSETTE TO PROTECT AGAINST UNCONTROLLED GRAVITY INFUSIONS; PUMP COMES WITH SMART SITE NEEDLE FREE VALVE PORTS; 1PG 6515-01-452-3445 AND 1PG 6515-01-416-4032; THIS ITEM IS AIRWORTHY FOR A FIXED WING/ROTARY AIRCRAFT REQUISITIONER SHOULD SPECIFY IF DIRECTIONS FOR USE & FIELD MAINTENANCE SOFTWARE IS REQUIRED VAC. 3 total characteristics are documented in the Federal Logistics Information System.