PartsTable TECHNICAL DATA SHEET
NSN 6515-01-539-6607Government record, cited

Tester, Electrocardiograph and Ca6515-01-539-6607

NSN 6515-01-539-6607 · NIIN 015396607 · Part number XR300
Datrix Corp Dba Hardlink · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0X3N7
Government record, cited
NSN 6515-01-539-6607 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-539-6607. Manufacturer of record part number: XR300.
Also searched as  6515-01-539-6607 · 6515015396607 · NIIN 015396607 · 01-539-6607 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 0X3N7 · XR300
Nearby stock numbers  ·
Features
  • Tester,electrocardiograph and Ca — FSC 6515
  • Shape: RECTANGULAR
  • 1 manufacturer part number on file
  • Manufacturer of record: Datrix Corp Dba Hardlink
Identification
  • NSN: 6515-01-539-6607
  • NIIN: 015396607
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: XR300
  • Manufacturer: Datrix Corp Dba Hardlink
General Description

The Tester,electrocardiograph and Ca, cataloged under National Stock Number 6515-01-539-6607, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Datrix Corp Dba Hardlink. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-539-6607
Primary Part NumberXR300
Item NameTester,electrocardiograph and Ca
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerDatrix Corp Dba Hardlink
StatusACTIVE
ShapeRECTANGULAR
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
XR300 PRIMARY Datrix Corp Dba Hardlink (USA)
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY
Related Parts in Medical, Dental, and Veterinary Equipment
6515-00-000-0069
ELECTROSURGICAL APPARATUS
SURGISTAT II WITH ACCESSORIES
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
8963
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-539-6607?

NSN 6515-01-539-6607 is a Tester,electrocardiograph and Ca, manufactured by Datrix Corp Dba Hardlink, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-539-6607?

NSN 6515-01-539-6607 has 1 manufacturer part number on file: XR300 (Datrix Corp Dba Hardlink).

What are the specifications of XR300?

Key specifications for XR300: Shape: RECTANGULAR; Special Features: ANALOG CASSETTE HOLTER RECORDER; RUNS UP TO 5 ECG TESTS ON ONE BATTERY; LCD CLOCK; AUTO SHUTOFF; INTERNAL SELF TEST; FAILSAFE PATIENT EVENT BUTTON; BUILT IN CALIBRATOR; 3 CHANNEL ECG, 1 TIMING; 4 CHANNEL RECORDING HEAD; 9 VDC BATTERY; OPERATES IN ANY POSITION; OP TEMP P5/P45 DEG C; CONSISTS OF: 5/7 LEAD CABLE; CARRYING CASE; OP MANUAL; STD 24 HR RECORDING TIME; USES NORMAL BIAS TAPES C60/90/120 VDC. 1 specification is documented in the U.S. Government catalog.

Is NSN 6515-01-539-6607 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com