PartsTable TECHNICAL DATA SHEET
NSN 6515-01-537-4013Government record, cited

Probe, General Operating6515-01-537-4013

NSN 6515-01-537-4013 · NIIN 015374013 · Part number 5J70-001
Vysis Inc /del/ · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 03PQ2
Government record, cited
NSN 6515-01-537-4013 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-537-4013. Manufacturer of record part number: 5J70-001.
Also searched as  6515-01-537-4013 · 6515015374013 · NIIN 015374013 · 01-537-4013 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 03PQ2 · 5J70-001 · 5J7001
Nearby stock numbers  ·
Features
  • Probe,general Operating — FSC 6515
  • Design Designation: MULTIPLE DIAGNOSTIC TESTING
  • 1 manufacturer part number on file
  • Manufacturer of record: Vysis Inc /del/
Identification
  • NSN: 6515-01-537-4013
  • NIIN: 015374013
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 5J70-001
  • Manufacturer: Vysis Inc /del/
General Description

The Probe,general Operating, cataloged under National Stock Number 6515-01-537-4013, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Vysis Inc /del/. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-537-4013
Primary Part Number5J70-001
Item NameProbe,general Operating
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerVysis Inc /del/
StatusACTIVE
Design DesignationMULTIPLE DIAGNOSTIC TESTING
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
5J70-001 PRIMARY Vysis Inc /del/ (USA)
Reference documents
ReferenceMeaning
5J7001 5/9 Secondary reference
Vysis Inc /del/
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-537-4013?

NSN 6515-01-537-4013 is a Probe,general Operating, manufactured by Vysis Inc /del/, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-537-4013?

NSN 6515-01-537-4013 has 1 manufacturer part number on file: 5J70-001 (Vysis Inc /del/).

What are the specifications of 5J70-001?

Key specifications for 5J70-001: Design Designation: MULTIPLE DIAGNOSTIC TESTING; Special Features: MIXTURE OF THE LSI PML PROBE LABELED WITH SPECTRUMORANGE AND THE LSI RARA PROBE LABELED WITH SPECTRUMGREEN.THE PML PROBE COVERS THE REGION THAT BEGINS AT INTRON 7,A SPAN OF 5.8 KB,AND EXTENDS TOWARD THE CENTROMERE OF CHROMOSOME 15 FOR APPROXIMATELY 180 KB.THE RARA PROBE BEGINS ABOUT500 BP 3 TO EXON6 AND EXTENDS APPROXIMATELY 400 KB TOWARD THE TELOMERE OF CHROMOSOME 17 KB; Part Name Assigned by Controlling Agency: LSI/RARA DUALCOLOR TRANSLOCATION PROBE. 1 specification is documented in the U.S. Government catalog.

Is NSN 6515-01-537-4013 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com