PartsTable TECHNICAL DATA SHEET
NSN 6515-01-522-4385Government record, cited

Blanket, Hypothermia6515-01-522-4385

NSN 6515-01-522-4385 · NIIN 015224385 · Part number 200-9103-01-00E
Marketing Assessment, Inc. · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0YUT2
Government record, cited
NSN 6515-01-522-4385 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-522-4385. Manufacturer of record part number: 200-9103-01-00E.
Also searched as  6515-01-522-4385 · 6515015224385 · NIIN 015224385 · 01-522-4385 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 0YUT2 · 200-9103-01-00E · CHILL BUSTER · 04-1001 · 6532NCM040854
Nearby stock numbers  ·
Features
  • Blanket,hypothermia — FSC 6515
  • 1 manufacturer part number on file
  • Manufacturer of record: Marketing Assessment, Inc.
Identification
  • NSN: 6515-01-522-4385
  • NIIN: 015224385
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 200-9103-01-00E
  • Manufacturer: Marketing Assessment, Inc.
General Description

The Blanket,hypothermia, cataloged under National Stock Number 6515-01-522-4385, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Marketing Assessment, Inc.. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-522-4385
Primary Part Number200-9103-01-00E
Item NameBlanket,hypothermia
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerMarketing Assessment, Inc.
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
200-9103-01-00E PRIMARY Marketing Assessment, Inc. (USA)
Reference documents
ReferenceMeaning
CHILL BUSTER 5/1 Secondary reference
Marketing Assessment, Inc.
04-1001 5/1 Secondary reference
U.S. Government activity
6532NCM040854 5/1 Secondary reference
Defense Medical Standardization Board

Frequently Asked Questions

What is NSN 6515-01-522-4385?

NSN 6515-01-522-4385 is a Blanket,hypothermia, manufactured by Marketing Assessment, Inc., classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-522-4385?

NSN 6515-01-522-4385 has 1 manufacturer part number on file: 200-9103-01-00E (Marketing Assessment, Inc.).

What are the specifications of 200-9103-01-00E?

Key specifications for 200-9103-01-00E: Overall Length: 60.000 INCHES NOMINAL IN; Overall Width: 30.000 INCHES NOMINAL IN; Special Features: SPECIFICALLY DESIGNED TO TREAT HYPOTHERMIA ENCOUNTERED IN THE FIELD, AND IN PRE-HOSPITAL, HOSPITAL OR SURGICAL ENVIRONMENTS; USER-SET TEMP RANGE OF 65 TO 105 DEG F FOR CONTROLLED WARMING; 1.75-3.5 HR OF OPERATION, ALLOWING FOR EXTENDED PATIENT TRANSPORT; BLANKET WIRE HEATS TO 105 DEG F WITHIN 60 SEC FOR RAPID THERMAL RESPONSE; AC/DC CONVERTER PERMITS THE ALTERNATIVE OF LINE POWER OPERATION TO ENHANCE OPERATION FLEXIBILTY; ELECTROMAGNETIC RADIATION AND SUSCEPTIBILITY MEETS THE IEC 60101 STANDARD; BLANKET DESIGN PERMITS REPEATED MACHINE WASHING AND DRYING; HARDWARE EASILY CLEANED AND DISINFECTED USING STANDARD MEDICAL AGENTS DEGF; Part Name Assigned by Controlling Agency: BLANKET 30" X 60" USED TO WARM PATIENT WHILE ATTACHED TO PATIENT WARMING SYSTEM NSN 6515-01-500-6087. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-522-4385 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com