The Vitrectomy Kit,ophthalmology, cataloged under National Stock Number 6515-01-520-7281, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Becton, Dickinson and Co Dba Becton Dickinson & Co. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-520-7281 |
| Primary Part Number | 585136 |
| Item Name | Vitrectomy Kit,ophthalmology |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Becton, Dickinson and Co Dba Becton Dickinson & Co |
| Status | ACTIVE |
| Features Provided | STERILE |
| Component and Quantity | VITRECTOMY UNIT,1; GUILLOTINE CUTTER,2 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 585136 PRIMARY | Becton, Dickinson and Co Dba Becton Dickinson & Co (USA) |
| Reference | Meaning |
|---|---|
| 04-0711 | 5/1 Secondary reference U.S. Government activity |
| 6515NCM991090 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6515-01-520-7281 is a Vitrectomy Kit,ophthalmology, manufactured by Becton, Dickinson and Co Dba Becton Dickinson & Co, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-520-7281 has 1 manufacturer part number on file: 585136 (Becton, Dickinson and Co Dba Becton Dickinson & Co).
Key specifications for 585136: Features Provided: STERILE; Component and Quantity: VITRECTOMY UNIT,1; GUILLOTINE CUTTER,2; Special Features: IDEAL WHEN EMERGENCY ANTERIOR SEGMENT VITRECTOMY IS REQUIRED FOR EYE TRAUMA COMPLICATIONS DURING CATARCT SURGERY OR CORNEAL TRANSPLANT; TIP: .90 (20G), 14MM SLEEVE; GAUGE: 20; DIAM.: 90MM CUTTING PROPE W/1.4MM REMOVALBE IRRIGATION SLEEVE; STERILE G; Part Name Assigned by Controlling Agency: VITRECTOMY AUTOMATED ANTERIOR HANDHELD. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.