PartsTable TECHNICAL DATA SHEET
NSN 6515-01-518-4101Government record, cited

Simulator, Pulse Oximeter6515-01-518-4101

NSN 6515-01-518-4101 · NIIN 015184101 · Part number INDEX 2XLFE
Fluke Biomedical Corporation · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 34511
Government record, cited
NSN 6515-01-518-4101 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-518-4101. Manufacturer of record part number: INDEX 2XLFE.
Also searched as  6515-01-518-4101 · 6515015184101 · NIIN 015184101 · 01-518-4101 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 34511 · INDEX 2XLFE · 1058497 · 04-0271 · 6515NCM040117 · 2395309
Nearby stock numbers  ·
Features
  • Simulator,pulse Oximeter — FSC 6515
  • 3 manufacturer part numbers on file
  • Manufacturer of record: Fluke Biomedical Corporation
Identification
  • NSN: 6515-01-518-4101
  • NIIN: 015184101
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: INDEX 2XLFE
  • Manufacturer: Fluke Biomedical Corporation
General Description

The Simulator,pulse Oximeter, cataloged under National Stock Number 6515-01-518-4101, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Fluke Biomedical Corporation. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-518-4101
Primary Part NumberINDEX 2XLFE
Item NameSimulator,pulse Oximeter
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerFluke Biomedical Corporation
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6625-01-669-93502395309 POSSIBLE MATCH
TESTER,SAFETY,ELECTRICAL MEDICAL
Possible match (shared part number)Fluke Corp
Cross-Reference Index
Part NumberManufacturer
1058497 Ugap (FRA)
INDEX 2XLFE PRIMARY Fluke Biomedical Corporation (USA)
2395309 Gamida Sa (FRA)
Reference documents
ReferenceMeaning
04-0271 5/1 Secondary reference
U.S. Government activity
6515NCM040117 5/1 Secondary reference
Defense Medical Standardization Board
Related Parts
6625-01-669-9350POSSIBLE MATCH
TESTER,SAFETY,ELECTRICAL MEDICAL
2395309

Frequently Asked Questions

What is NSN 6515-01-518-4101?

NSN 6515-01-518-4101 is a Simulator,pulse Oximeter, manufactured by Fluke Biomedical Corporation, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-518-4101?

NSN 6515-01-518-4101 has 3 manufacturer part numbers on file: 1058497 (Ugap), INDEX 2XLFE (Fluke Biomedical Corporation), 2395309 (Gamida Sa).

What NSN replaces 6515-01-518-4101?

1 possible match (shared part number, not a government interchangeability claim): 6625-01-669-9350. Verify interchangeability with system specifications before substitution.

What are the specifications of INDEX 2XLFE?

Key specifications for INDEX 2XLFE: Overall Height: 9.000 INCHES NOMINAL IN; Overall Length: 16.000 INCHES NOMINAL IN; Overall Width: 18.000 INCHES NOMINAL IN; Special Features: OPTICAL FINGER WITH ENHANCED OPTICS FOR A MORE PHYSIOLOGICAL FINGER, ELECTRICAL SIMULATIONS AND PROBE TESTING; COMPATIBLE WITH ANY PULSE OXIMETER; PORTABLE; 6 DOWNLOADS R-CURVE SPACES; PHYSIOLOGICAL FINGER FOR SPO2 TEST; TO SIMULATE ARTERIAL OXYGEN SATURATION FROM 35% TO 100% OXYGENATION; HEART RATE CAN BE VARIED FROM 30-250 BBM; WEIGHT: 10LBS; LCD DISPLAY LBS. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-518-4101 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com