PartsTable TECHNICAL DATA SHEET
NSN 6515-01-506-9652Government record, cited

Screw, Bone6515-01-506-9652

NSN 6515-01-506-9652 · NIIN 015069652 · Part number 214.818
Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 63075
Government record, cited
NSN 6515-01-506-9652 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-506-9652. Manufacturer of record part number: 214.818.
Also searched as  6515-01-506-9652 · 6515015069652 · NIIN 015069652 · 01-506-9652 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 63075 · 214.818 · 03-0607 · 6515NCM030279
Nearby stock numbers  ·
Features
  • Screw,bone — FSC 6515
  • Outside Thread Diameter: 4.5 MILLIMETERS NOMINAL MM
  • Thread Direction: RIGHT-HAND
  • Casehardening Indicator: NOT CASEHARDENED
  • Material: STEEL CORROSION RESISTING OVERALL
  • 3 manufacturer part numbers on file
  • Manufacturer of record: Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma
Identification
  • NSN: 6515-01-506-9652
  • NIIN: 015069652
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 214.818
  • Manufacturer: Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma
General Description

The Screw,bone, cataloged under National Stock Number 6515-01-506-9652, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma. Government technical data includes 4 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6515-01-506-9652
Primary Part Number214.818
Item NameScrew,bone
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerDepuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma
StatusACTIVE
Outside Thread Diameter4.5 MILLIMETERS NOMINAL MM
Thread DirectionRIGHT-HAND
Casehardening IndicatorNOT CASEHARDENED
MaterialSTEEL CORROSION RESISTING OVERALL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
214.818 PRIMARY Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma (USA)
214.818 Mathys Robert Dr Manufacturing Co. (CHE)
214.818 Johnson Johnson Medical SAS (FRA)
Reference documents
ReferenceMeaning
03-0607 5/1 Secondary reference
U.S. Government activity
6515NCM030279 5/1 Secondary reference
Defense Medical Standardization Board
214.818 5/9 Secondary reference
Depuy France
214.818 5/9 Secondary reference
Synthes

Frequently Asked Questions

What is NSN 6515-01-506-9652?

NSN 6515-01-506-9652 is a Screw,bone, manufactured by Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-506-9652?

NSN 6515-01-506-9652 has 3 manufacturer part numbers on file: 214.818 (Depuy Synthes Sales Inc Dba Depuy Synthes Trauma Div Depuy Synthes Sales, Inc., D/b/a Depuy Synthes Trauma), 214.818 (Mathys Robert Dr Manufacturing Co.), 214.818 (Johnson Johnson Medical SAS).

What are the specifications of 214.818?

Key specifications for 214.818: Outside Thread Diameter: 4.5 MILLIMETERS NOMINAL MM; Thread Direction: RIGHT-HAND; Casehardening Indicator: NOT CASEHARDENED; Special Features: 4.5MM DIAMETER; 18MM LENGTH; SELF-TAPPING; CORTEX MM. 4 specifications are documented in the U.S. Government catalog.

Is NSN 6515-01-506-9652 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com