The Vitreoretinal,surgical System, cataloged under National Stock Number 6515-01-486-5835, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 1 specification, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6515-01-486-5835 |
| Item Name | Vitreoretinal,surgical System |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Status | ACTIVE |
| Supplementary Features | ASPIRATION: VACUUM 0 TO 500 MMHG; MAX INCREMENTS: 5 MMHG; RISE TIME: ADJ 250 MS TO 10 SEC STORAGE CAPACITY: 300 ML; 25 PSI OUTPUT FOR PNEUMATIC DRIVEN VITRECTORS CUTS/MIN: 5 TO 2000; CONTROL INCREMENTS: 5 CUTS/MIN; SINGLE CUT MODE; AIR PRESSURE 1 TO 100 MMHG, 1 MMHG INCREMENT FLUID AIR EXCHANGE; TRIPLE OUTPUT TRUE WHITE LIGHT DIMMING AUTO BACK UP TUNGSTEN-HALOGEN BULB; LINEAR CONTROL W/SIDE SWITCHES FOOTPEDAL; PHACOEMULSIFICATION HANDPIECE; OP FREQ: 40 KHZ; 1 TO 20 HZ PULSE MODE; TITANIUM CASING; PIEZOELECTRIC TRANSDUCER; DIMENSIONS: 6 X 21 X 19; WEIGHT: 45 LBS; NO EXTERNAL AIR PRESSURE REQUIRED KHz |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Reference | Meaning |
|---|---|
| 01-0349 | 3/2 Design control — primary reference U.S. Government activity |
NSN 6515-01-486-5835 is a Vitreoretinal,surgical System, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
Key specifications for 6515-01-486-5835: Supplementary Features: ASPIRATION: VACUUM 0 TO 500 MMHG; MAX INCREMENTS: 5 MMHG; RISE TIME: ADJ 250 MS TO 10 SEC STORAGE CAPACITY: 300 ML; 25 PSI OUTPUT FOR PNEUMATIC DRIVEN VITRECTORS CUTS/MIN: 5 TO 2000; CONTROL INCREMENTS: 5 CUTS/MIN; SINGLE CUT MODE; AIR PRESSURE 1 TO 100 MMHG, 1 MMHG INCREMENT FLUID AIR EXCHANGE; TRIPLE OUTPUT TRUE WHITE LIGHT DIMMING AUTO BACK UP TUNGSTEN-HALOGEN BULB; LINEAR CONTROL W/SIDE SWITCHES FOOTPEDAL; PHACOEMULSIFICATION HANDPIECE; OP FREQ: 40 KHZ; 1 TO 20 HZ PULSE MODE; TITANIUM CASING; PIEZOELECTRIC TRANSDUCER; DIMENSIONS: 6 X 21 X 19; WEIGHT: 45 LBS; NO EXTERNAL AIR PRESSURE REQUIRED KHz; Special Features: COMPLETE WITH LIGHT SOURCE, AIR/FLUID EXCHANGE, LINEAR FOOT PEDAL, DISK DRIVE, ULTRASOUND WITH HANDPIECE, VITRECTOR DRIVE WITH ASPIRATION; TRIPLE-PORT WITH SINGLE BULB WITH BACKUP BULB; WIDE ANGLE FIBERS, ILLUMINATED MEMBRANE PICKS, ILLUMINATED END IRRIGATORS AND BARE ENDED FIBERS FOR FORCEPS, SCISSORS AS WELL AS STANDARD FIBERS; VITRECTOR DRIVE OPERATION: 5-2000 CPM/CAPABLE OF DRIVING VERTICAL SCISSORS FROM 1-350 CPM; HIGH FLOW HIGH SPEED VITRECTOR TO 2000 CPM ENABLES CORE VITRECTOMY AT 1500 CPM AND RETINAL SHAVING AT 2000 CPM; INTERNAL AIR PUMPS CAN BE USED AS MAIN SUPPLY OR BACKUP; USER FRIENDLY FRONT PANEL DESIGNED FOR UP TO 12 SURGEONS; SOFTWARE STORES UP TO 7 PARAMETERS OF SURGERY; DISK DRIVE ENABLES SURGEONS TO STORE PARAMETERS, TO DOWNLOAD FUTURE SOFTWARE UPDATES AND PROVIDE DIAGNOSTIC INFORMATION FOR TRANSMITTAL BY EMAIL; Part Name Assigned by Controlling Agency: VITREORETINAL SURGICAL SYSTEM. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.