PartsTable TECHNICAL DATA SHEET
NSN 6515-01-476-9961Government record, cited

Simulator, Oximeter6515-01-476-9961

NSN 6515-01-476-9961 · NIIN 014769961 · Part number SP02INDEX2PFE
Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc. · FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 56198
Government record, cited
NSN 6515-01-476-9961 — this item is cataloged by the U.S. Government under National Stock Number 6515-01-476-9961. Manufacturer of record part number: SP02INDEX2PFE.
Also searched as  6515-01-476-9961 · 6515014769961 · NIIN 014769961 · 01-476-9961 · FSC 6515 Medical and Surgical Instruments, Equipment, and Supplies · CAGE 56198 · SP02INDEX2PFE · SP02INDEX2FE
Nearby stock numbers  ·
Features
  • Simulator,oximeter — FSC 6515
  • General Characteristics Item Description: CAN TEST THE OXIMETER W/O THE PROBE IN-LINE;PROBE ANALYSIS INCLUDES: LED TEST - VOLTAGE DROP ACROSS BOTH RED AND INFRARED DIODES, PHOTODIODE TEXT DETECTOR RESPONSE TO A 1MA ILLUMINATING CURRENT AND RESISTANCE BETWEEN ALL WIRES;CAN SIMULATE ARTERIAL OXYGEN SATURATION FROM 35-100 PCT OXYGENATION;SIMUULATES PATIENT CONDITIONS SUCH AS NORMAL, WEAK PULSE, GERIATRIC, OBESE, BRADYCARDIA AND TACHYCARDIA; PORTABLE;9 PRELOAD MANUFACTURERS R-CURVES;5 DOWNLOADALE R-CURVES;PHYSIOLOGICAL FINGER FOR SP02 TEST;RS232 PORT; PHYSIOLOGICAL MOTION ARTIFACT;HEARTRATE RANGE: 30-250 BPM: RESOLUTION: 1 BPM;PULSE AMPLITUDE RANGE: 0-20 PCT PERFUSION, RESOLUTION: 1 PCT; 2-LINE X 24-CHARACTER SUPER TWIST LCD DISPLAY
  • 1 manufacturer part number on file
  • Manufacturer of record: Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc.
Identification
  • NSN: 6515-01-476-9961
  • NIIN: 014769961
  • FSC: 6515 — Medical and Surgical Instruments, Equipment, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: SP02INDEX2PFE
  • Manufacturer: Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc.
General Description

The Simulator,oximeter, cataloged under National Stock Number 6515-01-476-9961, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc.. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6515-01-476-9961
Primary Part NumberSP02INDEX2PFE
Item NameSimulator,oximeter
FSC / FSG6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies
ManufacturerBiotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc.
StatusACTIVE
General Characteristics Item DescriptionCAN TEST THE OXIMETER W/O THE PROBE IN-LINE;PROBE ANALYSIS INCLUDES: LED TEST - VOLTAGE DROP ACROSS BOTH RED AND INFRARED DIODES, PHOTODIODE TEXT DETECTOR RESPONSE TO A 1MA ILLUMINATING CURRENT AND RESISTANCE BETWEEN ALL WIRES;CAN SIMULATE ARTERIAL OXYGEN SATURATION FROM 35-100 PCT OXYGENATION;SIMUULATES PATIENT CONDITIONS SUCH AS NORMAL, WEAK PULSE, GERIATRIC, OBESE, BRADYCARDIA AND TACHYCARDIA; PORTABLE;9 PRELOAD MANUFACTURERS R-CURVES;5 DOWNLOADALE R-CURVES;PHYSIOLOGICAL FINGER FOR SP02 TEST;RS232 PORT; PHYSIOLOGICAL MOTION ARTIFACT;HEARTRATE RANGE: 30-250 BPM: RESOLUTION: 1 BPM;PULSE AMPLITUDE RANGE: 0-20 PCT PERFUSION, RESOLUTION: 1 PCT; 2-LINE X 24-CHARACTER SUPER TWIST LCD DISPLAY
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
SP02INDEX2PFE PRIMARY Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc. (USA)
Reference documents
ReferenceMeaning
SP02INDEX2FE 5/9 Secondary reference
Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc.
No interchangeability data on file.
Other items in FSC 6515 — Medical and Surgical Instruments, Equipment, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6515-00-000-0069
ELECTROSURGICAL APPARATUS
6515-00-001-7679
6515-00-001-7679 · Item name not on file
6515-00-001-7680
SYRINGE AND NEEDLE,HYPODERMIC
6515-00-001-7681
6515-00-001-7681 · Item name not on file
6515-00-001-7682
6515-00-001-7682 · Item name not on file
6515-00-001-7683
BLOOD RECIPIENT SET,INDIRECT TRA
6515-00-001-9178
6515-00-001-9178 · Item name not on file
6515-00-001-9180
TUBE,TRACHEOSTOMY

Frequently Asked Questions

What is NSN 6515-01-476-9961?

NSN 6515-01-476-9961 is a Simulator,oximeter, manufactured by Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc., classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.

What part numbers are listed for NSN 6515-01-476-9961?

NSN 6515-01-476-9961 has 1 manufacturer part number on file: SP02INDEX2PFE (Biotek Instruments, Inc. Dba Biotek Div Bio-Tek Instruments Llc Dba Biotek Instruments Inc.).

What are the specifications of SP02INDEX2PFE?

Key specifications for SP02INDEX2PFE: General Characteristics Item Description: CAN TEST THE OXIMETER W/O THE PROBE IN-LINE;PROBE ANALYSIS INCLUDES: LED TEST - VOLTAGE DROP ACROSS BOTH RED AND INFRARED DIODES, PHOTODIODE TEXT DETECTOR RESPONSE TO A 1MA ILLUMINATING CURRENT AND RESISTANCE BETWEEN ALL WIRES;CAN SIMULATE ARTERIAL OXYGEN SATURATION FROM 35-100 PCT OXYGENATION;SIMUULATES PATIENT CONDITIONS SUCH AS NORMAL, WEAK PULSE, GERIATRIC, OBESE, BRADYCARDIA AND TACHYCARDIA; PORTABLE;9 PRELOAD MANUFACTURERS R-CURVES;5 DOWNLOADALE R-CURVES;PHYSIOLOGICAL FINGER FOR SP02 TEST;RS232 PORT; PHYSIOLOGICAL MOTION ARTIFACT;HEARTRATE RANGE: 30-250 BPM: RESOLUTION: 1 BPM;PULSE AMPLITUDE RANGE: 0-20 PCT PERFUSION, RESOLUTION: 1 PCT; 2-LINE X 24-CHARACTER SUPER TWIST LCD DISPLAY. 1 specification is documented in the U.S. Government catalog.

Is NSN 6515-01-476-9961 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com