The Electrosurgical Apparatus, cataloged under National Stock Number 6515-01-460-6050, is classified within Federal Supply Class 6515 (Medical and Surgical Instruments, Equipment, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Tyco Healthcare Group Lp Dba Covidien Div Valleylab. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6515-01-460-6050 |
| Primary Part Number | FORCE FX SYSTEM |
| Item Name | Electrosurgical Apparatus |
| FSC / FSG | 6515 / 65 — Medical and Surgical Instruments, Equipment, and Supplies |
| Manufacturer | Tyco Healthcare Group Lp Dba Covidien Div Valleylab |
| Status | ACTIVE |
| Frequency Rating | 60.0 HERTZ NOMINAL |
| Installation Design | PORTABLE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| FORCE FX | Southern Syringe Services Ltd (GBR) |
| FORCE FX | Covidien (uk) Commercial Ltd (GBR) |
| FORCE FX SYSTEM PRIMARY | Tyco Healthcare Group Lp Dba Covidien Div Valleylab (USA) |
NSN 6515-01-460-6050 is a Electrosurgical Apparatus, manufactured by Tyco Healthcare Group Lp Dba Covidien Div Valleylab, classified under FSC 6515, Medical and Surgical Instruments, Equipment, and Supplies. Status: active.
NSN 6515-01-460-6050 has 3 manufacturer part numbers on file: FORCE FX (Southern Syringe Services Ltd), FORCE FX (Covidien (uk) Commercial Ltd), FORCE FX SYSTEM (Tyco Healthcare Group Lp Dba Covidien Div Valleylab).
Key specifications for FORCE FX SYSTEM: Special Features: THE FORCE-FX SYSTEM SHALL CONSIST OF THE FOLLOWING PARTS: (1) FORCE-FX-C GENERATOR,(1) E6008, MONOPOLAR FOOTSWITCH,(1) E6009, BIPOLAR FOOTSWITCH,(1) E2515H, ROCKER SWITCH PENCIL, STAINLESS STEEL W/HOLSTER,(1) E1550, BALL ELECTRODE,5MM,(1) E14506 EDGE COATED BLADE ELECTRODE,6IN.(1) E1452 NEDGE NEEDLEEL ECTRODE,(1) E05021, MONOPOLAR ADAPTER,(1) E0560, REUSABLE CORD FOR PATIENT RETURN ELECTRODE,(1) E7509, PATIENT RETURNE ELECTRODE, REM, CORDLESS, AND (1)U C8009 UNIVERSAL CART; USER MUST SPECIFY VOLTAGE REQUIRED EITHER 110/60 OR 220/50 MM; Frequency Rating: 60.0 HERTZ NOMINAL; Installation Design: PORTABLE. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.